kvm-tec | 15
2. installation of the extender
To install the product with/without Network Switch:
1. Position the
uVX1/local unit/CPu
(A) close to the host computer.
2. Position the
uVX1/remote unit/CON
(B) at the desired location.
3. If you are using a Network Switch, position the device between the
uVX1/local unit/CPu
and the
uVX1/remote/CON/ unit
. Note: the maximum distance between the UVX1 units
with CAT7cable is 100 meter (328 ft) . The maximum distance between the UVX1-F extenders
with fibre cable in the single mode is 20 kilometer ( 12.42 miles) , with multimode is
300 meter (984 ft) - Standard
4. Connect a monitor to the
DP-out
(7) on the
uVX1/local/CPuunit
(A) - If a local Monitor is
required ( optional)
5. Connect one end of the supplied
DP-cable
(D) to the
DP-in
(1) on the
uVX1/local unit
(A).
6. Connect the other end of the supplied
DP-cable
(D) to the DP connection on your
computer.
7. Connect one end of the supplied
uSB cable
(E) to the
uSB connection
(5) on the
uVX1/local unit
(A).
8. Connect the other end of the supplied
uSB cable
(E) to a USB port on your computer.
9. Connect a monitor to the
DP-out
(14) on the
uVX1/remote /CON unit
(B).
10. Connect a keyboard to a
uSB port
(11) on the
uVX1/remote/CON unit
(B).
11. Connect a mouse to a
uSB port
(11) on the
uVX1/remote/CON unit
(B)
12. Do one of the following, depending on your model and configuration:
• For the UVX1 with Network Switch (see chapter
Requirements
for cable requirements):
• Connect one end of a CAT7 cable (not included) to the
kvm-link port
(4) on the
uVX1/local unit
(A). Make sure that the plug is latched.
• Connect the other end of the CAT7 cable to one of the two CATx ports on the
Network Switch ( 10 G)
• Connect the end of a second CATx cable (not included) to the
kvm-link port
(4) on
the
uVX1/remote unit
(A). Make sure that the plug is latched.
• Connect the other end of the second CAT7 cable to the other CATx port on the
Network Switch ( 10 G)
• For the UVX1 without Network Switch (see chapter
Requirements
for cable requirements):
• Make sure the dust protectors on the Network Switch and Extenders have been
removed.
• Connect one end of the CAT7 cable (not included) to the
kvm-link port
(7 /21) on the
uVX1/local unit
(A). Make sure that the plug is latched.
• Connect the other end of the CAT7 cable to the
kvm-link port
(4) on
the
uVX1/remote unit (A)
. Make sure that the plug is latched.