1
54-0166 Addendum to Rev. B
TracVision 6 Technical
Manual Addendum
(ECO #s 5959, 5503, 5315, 6138, 6198)
The following changes have been made to Revision B of the
TracVision 6 Installation and Technical Manual (KVH Part
Number 54-0166).
3.1.1 Blown Fuse, Low Power, or Wiring
The 4-amp fuse on the
CPU Printed Circuit Board (PCB)
has been
replaced with two 3.15-amp fuses to better protect the Antenna Unit’s
electronics.
1. Blown Fuse – The Antenna Unit is equipped with
two fuses
mounted on its CPU Board. If
either of
these fuses
has blown or been broken, the
Antenna Unit will not operate. Refer to
Section 4.4,
“PCB Removal and Replacement,”
for details on the
fuse locations and how to access the CPU Board.
4.3
TracVision 6 Field
Replaceable Units
Table 4-1 has been updated to show the new part number for the
3.15-amp fuses and the new part numbers for the RF Detector PCB and
European LNB. The azimuth limit switch has also been added to the
list.
FRU
Part Number
Radome
02-1047-01
CPU
02-0992
RF Detector PCB
02-1237
Antenna Gyro Sensor
02-1035
Antenna Gyro Gasket
24-0139
Elevation Drive Belt
24-0105-83
Elevation Motor
02-1050
Azimuth Limit Switch Assembly
02-0957-01
Table 4-1
TracVision 6 Field
Replaceable Units