TracNet H60 Installation Guide
32
Terminating LMR-240 Cable
8.
Insert the end of the cable into the connector body
until the dielectric is firmly seated inside the connector.
Make sure there is no gap between the knurled end of
the connector and the cable jacket. Also be sure all
braid wires remain on the outside of the connector.
Figure 63: Pushing On the Connector
9.
Slide the ferrule over the braid until it is flush against
the connector shoulder.
Figure 64: Sliding the Ferrule over the Braid
10. Using an appropriate crimp tool, crimp the ferrule in
place. Crimp as close to the connector body as
possible.
Figure 65: Crimping the Ferrule onto the Cable
11. Slide the heat shrink sleeve over the connector body
and heat it to compress it into place.
Figure 66: Placing the Heat Shrink Tubing
IMPORTANT!
A common installation failure occurs when the
connector is not seated properly onto the cable. In
these cases, the cable’s center conductor does not fully
engage the electrical contacts inside the connector. To
ensure full engagement, make certain that there is no
gap between the cable jacket and the knurled end of
the connector before you crimp on the ferrule. You may
need to
center the end of the conductor
to achieve a
good fit.