15
TracNet H60 Installation Guide
Connect an NMEA Talker
Connect an NMEA Talker
The antenna
requires
a vessel heading input from a
customer-supplied NMEA 0183 or NMEA 2000 talker.
Optionally, you can also provide a vessel position input to
serve as a backup to the antenna’s built-in GPS.
NMEA 0183
1.
Connect the NMEA 0183 talker to the 2-position
terminal strip connector (
supplied in kit
), as shown in
Figure 27. Then plug the connector into the rear panel
of the BDU.
2.
Configure the NMEA device to transmit one or more of
the supported NMEA 0183 messages at 4800 baud.
3.
Make sure the data message(s) includes the
checksum, identifiable by a *xx field at the end of the
data sentence (e.g., $HEHDT,123.4, T*1F). See
“Verifying the NMEA 0183 Message” on page 36
for
details. Do not exceed a 10 Hz input rate.
Note:
To supply both the required heading and the
optional position to the BDU, you can either connect an
NMEA 0183 talker that transmits both messages, or
connect two devices using an NMEA data multiplexer, such
as Actisense
®
model NDC-4.
Figure 25: Supported NMEA 0183 Messages
NMEA 2000
1.
Connect the BDU to the vessel’s NMEA 2000 CAN
network backbone via a “T” connector. Be sure to use
a standard drop cable: 5-wire (4 cond shield)
twisted pair with micro-C connectors.
2.
Configure the NMEA device to transmit one or more of
the supported NMEA 2000 messages.
Figure 26: Supported NMEA 2000 Messages
Figure 27: NMEA Wiring
NMEA 0183 $--XXX
Description
Heading Messages
HDG
Heading, Deviation & Variation
HDM
Heading, Magnetic
HDT
Heading, True
OSD
Own Ship Data
THS
True Heading & Status
VHW
Water Speed and Heading
Position Message (Optional)
RMC
Position (Optional)
PGN
Description
Heading Messages
127250
Vessel Heading
Position Message (Optional)
129029
GNSS Position Data (Optional)