5-3
Maintenance
54-0149 Rev. D
5.4
Field Replaceable Unit
Procedures
The following subsections provide detailed procedures for
repairing or swapping out field replaceable units. The procedures
refer to labeled items presented on the following isometric
diagrams, which are based on KVH assembly drawings.
PCB Cover
PCB
Pan Head Screws
Rotating Plate
Pivot Bracket
Linear Actuator
Elevation Axis Motor Shaft
Quick Release Pin
Figure 5-2
Close-up of Linear Actuator,
Pivot Bracket, and Pin
Always lift the antenna unit by
the gray baseplate, never by the
radome or any portion of the
antenna assembly!
Figure 5-1
Antenna, PCB, and Rotating Plate