4. Remove 6 pan head screws from the PCB cover
flanges.
5. Remove the PCB cover. To get the necessary
clearance, rotate the linear actuator up 90º while
lifting the PCB cover
– Fig. 5-4
.
6. Remove cable connectors from PCB. Figure 5-5
illustrates the PCB arrangement and connector
locations.
7. The PCB is mounted to the rotating plate with
9 pan head screws.
8. Reverse this process to install the replacement
PCB. Reinstall all cable connectors removed in
Step 6.
9. Carry out the LNB calibration procedure
(
Section 5.4.2
).
3
A Guide to TracVision SA – ADDENDUM
54-0149 Addendum to Rev. D
! "#
$! % &
'( &
Figure 5-5
PCB Connector Locations –
Rear View
When replacing the PCB cover, be
careful not to pinch any cables.
TracVision SA is equipped with a
5x20 mm, 3.15-amp, 250-volt fast-
blow fuse, which is mounted on the
PCB. To access and replace the
fuse, remove the PCB cover.