3.3 Service Screens: Settings behind PIN Code
Screen 8: Pin code
Pincode 5
(farmers) gives entry to
the next fields and the first two
steps of the calibration.
(for changing the empty hopper
weight, extra extensions etc.)
Pincode 8
(service men) gives entry to
the next field and the total hopper
calibration can be done.
WARNING: Entering with Pin 8 may
only be done by professionals because
function of machine can be disturbed.
Limit for minimum fertiliser flow:
Below this value, the system will
not start the automatic calibration.
Number of load cells on the machine
4=TL, CL GEO, RO EDW, RO-M GEO
1= CL EW and RO-M EW
3= TL (old version)
Adjustable auto calibration times.
Big = 75 kg and 60 s
Medium= 50 kg and 45 s
Small = 35kg and 30 second
Serial number of machine (for
autoset app) (This box works
together with Top Service Tool.)
The value can only be changed
once. For second time Top Service
Tool needs to be used.
Screen 9: Settings screen
Here you can fill in where the TrimFlow
is mounted left, right, Center or Sensor
box.
Here you can filter the load cells (only
for EW)
3 Software screens
38
GEOSPREAD on/off (both active)
Sectioncontrol by dosing adjustment
(only the first active)
Содержание EDW2
Страница 3: ...1 System overview 3 ...
Страница 9: ...1 1 5 1 Battery cable 9 1 System overview ...
Страница 10: ...Relay connections Not available on spare parts 1 1 5 1 Battery cable 10 1 System overview ...
Страница 11: ...2 1 5 2 IM Tellus connection cable 11 1 System overview ...
Страница 12: ...1 5 3 ISOBUS connector 3 12 3 5 2 1 6 4 7 8 9 1 System overview ...
Страница 13: ...1 6 Communication and power cables Machine side 13 1 System overview ...
Страница 32: ...3 1 Machine Software overview EDW ISO II 1 19 3 Software screens 32 ...
Страница 74: ...Example 2 74 6 Implement setting GEOCONTROL ...