background image

 
 

______________________________________________________________________________________ 

4

 

EA04C

 

CAUTION 

Meggers  and  high  potential  test  equipment 
must  not  be  used.  Incorrect  use  of  such 
equipment  could  damage  the  semiconductors 
contained in the regulator. 

R

P

T

S

VAR

F-

EA04C

3

F+

4

VAR

1K OHM

Field

~

G

N

SW

1 2 3

SW

S

T

R

3

F+

F-

VAR

4

VAR

P

1

3

2

EA04C

1K OHM

G

Field

~

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8.  SW DESCRIPTION 

(1)  SW-1  Sensing voltage selector 

 

ON for 220V OFF for 380 / 480V. 

(2)  SW-2  Frequency selector 

 

ON for 50Hz OFF for 60Hz. 

(3)  SW-3  Response 

 

ON for fast OFF for slow. 

 
 
 
 
 
 
 
 
 
 

  Use only original supplied spare protection fuse for fuse replacement. 

  Please  accept  our  sincere  apology  if  any  modification  in  performance,  specification  or  appearance  is 

made without prior notice. 

  SW-1 OFF for 380/480VAC system 

(3Ø  4W 380/480 VAC) 

Figure 3 

 

SW-1 ON for 220VAC system 

Figure 4

 

SW

1 2 3

ON

AC Power Input : 

3, 4 

90 ~ 240VAC 50/60Hz 

Sensing Input : 

P, 4 

160 ~ 265VAC 50/60Hz 

 

300 ~ 550VAC 50/60Hz 

DC Output Power : 

F+, F

– 

Max 63VDC 4A 

EXT. VAR (1 K

Содержание EA04C

Страница 1: ... Qianzhen Dist Kaohsiung City 80664 Taiwan EA04C Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible replacement for Basler VR63 4 VR63 4A and Marathon SE100A Use for reference only and not genuine Basler product Use with Kutai EP200 Paralleling Module for parallel operation ...

Страница 2: ... 3mm H Weight 175 g 2 2 WIRING Refer to Figure 3 Power input 3 4 Sensing input 4 P F F Exciter EXT VAR External Voltage Adjustment 3 FREQUENCY COMPENSANION The frequency compensation characteristic to improve system load pickup performance by restraining voltage recovery until frequency has also started to recover For 50Hz system the regulator is preset at the factory for a 45Hz corner frequency F...

Страница 3: ...mprove and reduce the voltage change under heavy load 7 FIELD FLASHING When the regulator is operated with the generator for the first time the polarity residual magnetism may not correct or the magnitude not enough If the generator does not build up after startup shut down the prime mover and proceed with the following steps 1 With the prime mover at rest apply a dc source not grounded of not mor...

Страница 4: ...1 Sensing voltage selector ON for 220V OFF for 380 480V 2 SW 2 Frequency selector ON for 50Hz OFF for 60Hz 3 SW 3 Response ON for fast OFF for slow Use only original supplied spare protection fuse for fuse replacement Please accept our sincere apology if any modification in performance specification or appearance is made without prior notice SW 1 OFF for 380 480VAC system 3Ø 4W 380 480 VAC Figure ...

Отзывы: