ADVR-2200M

 

SECTION 1 : SPECIFICATION 

Sensing Input (E1, E2, E3) Average Reading 

Static Power Dissipation 

  Voltage 

220 

 600 Vac, 1 phase / 3 phase 

  Max. 12 watts 

   

DIP switch setting 

 

   

180 

 280 Vac @ 220 Vac 

Burden in SHUNT & PMG Wiring

 

   

330 

 515 Vac @ 380 / 440 Vac 

  550 VA @ power input 110 Vac 

   

420 

 660 Vac @ 480 / 600 Vac 

  1100 VA @ power input 220 Vac 

  Frequency 

50/60 Hz, DIP switch setting 

 

 

Quadrature Droop Input (C1, C2) 

Power Input (P1, P2)

 

  CT 1A or 5A greater than 5VA (DIP switch setting) 

  Voltage 

60 

 300 Vac, 1 phase 2 wire 

  Sensi/- 7% @ PF +/- 0.5 (Droop adjustable) 

  Frequency 

50 

 500 Hz 

 

 

Analogue Voltage Input (A1, A2) 

Auxiliary Input (P3, P4)

 

  Input resistance greater than 2K ohms 

  Voltage 

40 

 300 Vac, 1 phase 2 wire 

  Max. Input +/- 5 Vdc or +10 Vdc 

  Frequency 

40 

 500 Hz 

  Sensitivity 1 Vdc for 2.5% Generator Volts (adjustable) 

 

 

Excitation Output (F+, F-)

 

Under Frequency Protection (Factory Presets) 

  110V 1 phase Continuous 

63 Vdc 

3.5A 

  50 Hz system presets knee point at 45 Hz 

   

Max. 90 Vdc 7A for 10 secs. 

  60 Hz system presets knee point at 55 Hz 

  220V 1 phase Continuous 

125 Vdc  3.5A 

 

   

Max. 180 Vdc 7A for 10 secs. 

Over Excitation Protection 

  220V 3 phase Continuous 

150 Vdc  3.5A 

  Set point 125 Vdc +/- 4 % @ power input 220 Vac 

   

Max. 215 Vdc 7A for 10 secs. 

  Inverse-time curve. This function can be turned off. 

  Resistance 

  18 ohms @ power input 110 Vac 

 

   

  36 ohms @ power input 220 Vac 

Voltage Thermal Drift 

   

Max. 100 ohms 

  Less than 3% at temperature range -40 to +70 

˚C 

  Fuse Spec. 

Slow blow 5 x 20 mm S505-5A 

 

 

Under-Frequency Knee Point Thermal Drift 

External Voltage Adjustment (VR1, VR2)

 

  Less than +/- 0.1 Hz at -

40 to +70 ˚C 

  Max. +/- 5%  @ 500 ohms 1 watt potentiometer 

 

  Max. +/- 10%  @ 1K ohm 1 watt potentiometer 

Environment 

 

  Operating Temperature 

-40 to +60 

˚C 

Voltage Regulation

 

  Storage Temperature 

-40 to +85 

˚C 

  Less than +/- 0.5% ( with 4% engine governing ) 

  Relative Humidity 

Max. 95% 

 

  Vibration 

5.5 Gs @ 60 Hz 

Build Up Voltage

 

 

  5 Vac 25 Hz residual volts at power input terminal 

Dimensions 

 

  150.0 (L) x 135.0 (W) x 55.5 (H) mm 

Soft Start Ramp Time

 

  5.91 (L) x 5.31 (W) x 2.19 (H) inch 

  4 s/- 10% 

 

 

Weight 

Typical System Response 

  470 g +/- 2% 

  Less than 20 milliseconds 

  1.04 lb +/- 2% 

 

 

EMI Suppression 

 

  Internal electromagnetic interference filtering 

 

Содержание ADVR-2200M

Страница 1: ...0664 Taiwan ADVR 2200M Universal Hybrid Analog Digital Voltage Regulator Operation Manual Hybrid Universal Analog Digital 1 or 3 Phase 3 5 Amp Self Excited Shunt Auxiliary Winding Harmonic Power or PMG Automatic Voltage Regulator Easy to Set Up and Program Install Manual Use with KUTAI IVT 1260 IVT 2460 add on module can boost generator motor starting capacity ...

Страница 2: ...e point at 45 Hz Max 90 Vdc 7A for 10 secs 60 Hz system presets knee point at 55 Hz 220V 1 phase Continuous 125 Vdc 3 5A Max 180 Vdc 7A for 10 secs Over Excitation Protection 220V 3 phase Continuous 150 Vdc 3 5A Set point 125 Vdc 4 power input 220 Vac Max 215 Vdc 7A for 10 secs Inverse time curve This function can be turned off Resistance 18 ohms power input 110 Vac 36 ohms power input 220 Vac Vol...

Страница 3: ...l test equipment must not be used Use of such equipment could damage the AVR 3 Terminal Fast On terminals 6 35 mm 1 4 inch 4 Improper setting of under frequency protection could cause the output voltage of the unit to drop or become unstable under with changes in load Avoid making any changes to the U F setting unless necessary 5 Turn off O E in AVR when paralleling SECTION 3 DIP SWITCH PROGRAMMIN...

Страница 4: ...T Voltage Adjustment Generator rated output voltage adjustment Must be in accordance with the DIP Switch SW1 1 2 voltage range setting DIP U F Dip Adjustment When U F protection is activated the voltage droop ratio can be adjusted via this DIP POT The adjustable range is 3 10 V Hz STAB Stability Adjustment Correct stability adjustment must be conducted while the generator is operating without load...

Страница 5: ... ON Figure 6 ADVR 2200M IVT 1260 IVT 2460 Wiring Connection ATTENTION 1 All AC voltage readings are average value only 2 Use a remote 500 ohms 1 watt external VR for 5 adjustment range keep shorted if not used 3 Use a remote 1K ohm 1 watt external VR for 10 adjustment range 4 Sensing Voltage can be set from 220 600 Vac Program SW1 1 2 correctly 5 For single phase sensing bridge E2 E3 and move SW2 ...

Отзывы: