When the target passes the first reference point, press
and release the trigger once. When it passes the second
reference point, press the trigger a second time to stop the
timing function. The calculated average speed will be
shown under “Speed” in the LCD display window and the
time (in tenths of a second) will be shown under “Time” on
the LCD. Note that the time elapsed is shown in the HUD
until the speed is calculated and then the calculated
speed is shown in the HUD.
EXTERNAL OUTPUT SIGNAL
The I/O connector on the left side of the ProLaser III
provides a means to connect an external computer, data
storage or Giant Display device to the instrument. In a
typical application, this might be used to display or store
speed readings from the ProLaser III. The connector used
for this signal is a 6-pin DIN-style circular connector; if
you have trouble obtaining a compatible plug locally, the
mating part can be ordered through Kustom Signals'
Customer Service Department.
POWER CONSERVATION FEATURES
After approximately one minute with no activity, the
ProLaser III will enter a “sleep” mode. The display will
blank, and the message “Sleeping” will blink on the
display. To restore to normal operation, press any rear
panel switch (except PWR). The unit will also turn itself
off if no activity has occurred after a period of time in the
Sleep Mode. An audio chirp will sound to alert the
operator that the unit is powering down.
A locked speed or range will remain on the display
during “Sleep” mode, but the blink rate will be much
slower than when active. Pressing the trigger will clear
the display.