SECTION 6 - TESTING PROCEDURES
6.3
NOTE:
Only the actual Doppler signal is used for
the Patrol Speed. The speedometer input is
used only to steer or guide the DSP to search
for the Patrol Doppler signal in a specific
area, ignoring signals in other areas.
4. During normal operation, at patrol speeds below the
minimum limit of 16 km/h or when a “groundspeed”
Doppler signal cannot be found, the PATROL window
will display two dashes (--), indicating that the
speedometer speed is being received but a patrol speed
cannot be found or displayed. As an example, when a
patrol vehicle is slowing down and the speed drops
below the minimum speed, dashes will be displayed.
6.5 MINIMUM PATROL SPEED SET
1. When the speedometer input feature is not used, the
Falcon HR allows the operator to set a minimum patrol
speed of 16, 32, 48 or 64 km/h.
2. To activate this feature, place the unit in the moving
mode and press the PAT SEL switch one (1) time. The
unit will display “P” in the Patrol window and the last
selected minimum patrol speed will be displayed.
Default is the lowest value 16 km/h.
To change the value, immediately press the remote’s
LOCK/REL switch. Repeat until the desired value appears.
Once the desired minimum value is selected, the unit will
time out in 2 seconds and the last displayed value will be
accepted as the new minimum patrol speed.