INSTALLATION WIRING DIAGRAM
I. FOR BAR GRAPH DISPLAY, 091-200-IND OR DELUXE STATUS CENTER, 091-194C-IND
NOTE: Minimum wire size on charger BAT (+) and COM is 2
,
for a length of 20 feet. Smaller gauge wire may cause overheating of
terminal. Use 2S8R1 5/16” ring lug supplied with each charger to
terminate DC wires to battery. Additional information is available upon request.
# AWG
PIN-2: BLACK
WIRE SIZE
2 AWG
2 AWG
12 AWG
14/3 AWG
PIN-1: RED
PIN-3: WHITE
PIN-4: GREEN
NEGATIVE CHARGING LEAD
POSITIVE CHARGING LEAD
POSITIVE OUTPUT FOR AUX
AC INPUT POWER
COM
BAT +
AUX +
INPUT
DEFINITION
WIRE SIZE CHART
CONNECTION
R
E
M
O
T
E
AUX
12V
BAT OK
AC ON
AUX ON
AC
DC
5
SEN
IND
4
3
2
1
+
_
NEGATIVE OUTPUT FOR AUX
AUX -
12 AWG
A.C. INPUT POWER
GROUND (GRN)
LINE (BLK)
NEUTRAL (WHT)
DC OUTPUT
+
+
Chassis
Ground
Use 5/16 ring lug and M8 x 1.25
hardware, supplied. and Install rubber
terminal insulators over battery cable.
SUPPLIED
100 Amp circuit breaker;
place near battery
AUX+
L
N
AUX
Note:
For 240 VAC, pin-4 of indicator must go to pin-5 of
Remote Display on charger.
Note:
.
remote sense
wire cable voltage
compensation
CAUTION:
CHARGING LEADS MUST BE
DISCONNECTED FROM BATTERY
PRIOR TO WORKING ON CHARGER
Use 1/4 ring lug (2X), supplied.