Remote Charger Indicator Display:

The standard indicator displays the charge condition of the battery in 10-levels from “LOW 

CHARGE” to “FULLY CHARGED”.  This device indicates a defective battery when a bar 

graph does not rise to the “FULLY CHARGED” level after an extended period of charging.    

See option accessories for enhanced charger indicator displays.  

Note

: If a battery is being 

charged with an external load of 4 to 10 amperes across its terminals, the bar graph may 

move down 1 or 2 levels.  This does not indicate a defective battery.

 

LED Status Indicators:

• 

BATTERY OK

: Indicates that a battery of proper polarity is connected to the charger 

output terminals.

• 

AUX ON

: Indicates that power to the AUX output terminal is ON.

• 

AC ON

: Indicates that AC input voltage is present.  Note: Battery must be above 

9VDC and of proper polarity.

AUX Output:

The output terminal strip provides an additional output to accomodate 12 volt accessories, 

such as: Kussmaul's 12VDC  air pump.  The AUX output works in conjunction with a front 

panel mounted rocker switch.  For normal operation,  the rocker switch should be left in AC 

mode, which means that the aux accessory works only when shoreline power is supplied 

to the charger.  With the switch in DC mode the aux accessory will operate when AC power 

is ON or OFF.  In either position the aux output operates from the vehicle's batteries, while 

the charger automatically recharges the batteries as required.

AUX Output Automatic Reset Fuse:

The LPC contains an internal automatic reset fuse.  Should the AUX output fuse open, 

reset the fuse by cycling the AC input power (shore line).  Note:  the AUX rocker switch 

must be in AC mode.

AC Input Circuit Breaker Protection:

The charger AC input is circuit protected with a panel mounted manual reset circuit breaker.

 

Cooling Fan:

The LPC is fan cooled and turns on when the charger is on.  Air is circulated from the rear 

panel and exhusted through the front panel.

Reverse Polarity Protected (only when externally fused):

A surface mounted high current manual reset circuit breaker is provided with each charger.  

The circuit breaker must be installed with every charger to provide reverse polarity protection.  

If the circuit breaker is not installed then the charger will not be reverse polarity protected. 

Содержание 091-206-12-240

Страница 1: ...REV A REVISED BY THN PSS DATE 06 9 2014 INPUT 240 volt 50 60 Hz 6 5 amps OUTPUT 80 AMPERES AUTO CHARGE LPC SERIES MODEL 091 206 12 240 LPC STANDARD DISPLAY 170 Cherry Ave West Sayville NY 11796 www kussmaul com Phone 631 567 0314 Fax 631 567 5826 sales kussmaul com ...

Страница 2: ...TTERY PRIOR TO WORKING ON CHARGER 7 DC CONNECTION PRECAUTIONS a When connecting DC output wires to the charger always connect to the charger first and then to the battery b When disconnecting DC output wires to the charger always disconnect wires at the battery first and then disconnect wires at the charger 8 Charger Location a Locate charger as close to batteries as possible but not inside the ba...

Страница 3: ...switching technology the output terminal voltage is compared to a reference voltage any error detected is then used to control the charger output at the desired level There is no trickle charge and therefore no danger of overcharging and water boil off Automatic Current Limiting When batteries are severely discharged some battery chargers can be overloaded due to the high charging current required...

Страница 4: ...ted rocker switch For normal operation the rocker switch should be left in AC mode which means that the aux accessory works only when shoreline power is supplied to the charger With the switch in DC mode the aux accessory will operate when AC power is ON or OFF In either position the aux output operates from the vehicle s batteries while the charger automatically recharges the batteries as require...

Страница 5: ...hargerwillcontinuetochargethebatteryuntilthevoltageatthebatteryreaches float voltage level AUX Output 1 The AUX output is current limited to 15 amps via an internal automatic reset fuse The AUX output shares current demand with the battery output The combination of both outputs never exceeds 80 amps If the AUX output demands 15 amps then the battery output will be limited to 65 amps 2 The AUX outp...

Страница 6: ...reaker should be placed closest to battery terminal Torque rating 50in lb max 4 Double check all wiring before applying 240 AC volts to input terminal Verify that the battery voltage appears at the charger output terminals Note A minimum of 9 volts is required to start the charger 5 Apply 240 VAC shoreline power to input terminal and observe that the charger is operating The Remote Bar Graph need ...

Страница 7: ...NG LEAD POSITIVE OUTPUT FOR AUX AC INPUT POWER COM BAT AUX INPUT DEFINITION WIRE SIZE CHART CONNECTION REMOTE AUX 12V BAT OK AC ON AUX ON AC DC 5 SEN IND 4 3 2 1 _ NEGATIVE OUTPUT FOR AUX AUX 12 AWG A C INPUT POWER GROUND GRN LINE BLK NEUTRAL WHT DC OUTPUT Chassis Ground Use 5 16 ring lug and M8 x 1 25 hardware supplied and Install rubber terminal insulators over battery cable SUPPLIED 100 Amp cir...

Страница 8: ... SIZE CHART CONNECTION REMOTE AUX 12V BAT OK AC ON AUX ON AC DC 5 SEN IND 4 3 2 1 _ NEGATIVE OUTPUT FOR AUX AUX 12 AWG A C INPUT POWER GROUND GRN LINE BLK NEUTRAL WHT DC OUTPUT Chassis Ground Use 5 16 ring lug and M8 x 1 25 hardware supplied and Install rubber terminal insulators over battery cable SUPPLIED 100 Amp circuit breaker place near battery AUX L N AUX Note For 240 VAC pin 4 of indicator ...

Страница 9: ...OPTIONAL ACCESSORIES DELUXE STATUS CENTER MODEL 091 194C IND DELUXE STATUS CENTER WATERTIGHT MODEL 091 194C IND WT Bezel available in various colors red yellow white gray blue and black ...

Страница 10: ...it breaker Float Voltage 13 25 volts 0 80 amps Output Current 80 amperes max Status Indicators Battery OK AUX On Power On Charger Indicator See optional accessories Hardware Pack Includes 2 5 16 ring lugs p n 2S8R1 2 1 4 ring lugs p n 2S6R1 1 5 pin plug 1 2 pin plug 2 M8 x 1 25 bolt lockwasher and nut 2 Rubber terminal insulators 1 black 1 red 1 100amp Circuit Breaker p n 090 0100 0 Weight 10 poun...

Страница 11: ...use within 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of th...

Отзывы: