background image

INTRODUCTION

The AUTO CHARGE

d  

ODY charger, Model 091-128-12E-40-115 is a compact, com-

pletely automatic single channel battery charger designed specifically for periodic charg-
ing of ODYSSEY PC series and AGM Batteries.  Of rugged construction, the charger is
made to withstand the shock and vibration encountered in vehicle mounted equipment.
Utilizing components, which meet international safety standards, makes this charger
ideal for worldwide applications.

BATTERY CHARGER FEATURES

Completely automatic operation, charges battery on demand
Output Voltage regulated, eliminates overcharging battery
Output Voltage, temperature compensated (optional)
Output, current limited to protect charger from overloading
A 5-LED display indicating charge state and faults
Reverse polarity protection

INSTALLATION

The AUTO CHARGE

ODY should be installed in an area with adequate ventilation.

Mount the charger using the four holes provided.
Connect wiring from the battery to the output terminal strip.
Double check battery wiring.  Verify that the battery voltage appears at the charger
output terminals (See Figure 2).

Содержание 091-128-12E-40-115

Страница 1: ...0314 TOLL FREE 800 346 0857 FAX 631 567 5826 AUTO CHARGE ODY AUTOMATIC BATTERY CHARGER 3 YEAR WARRANTY MODEL 091 128 12E 40 115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the ODYSSEY requirementof 14 7 volts in the bulk absorption range and 13 6 volts in the float mode DO NOT USE TO CHARGE A NORMAL FLOODED LEAD ACID BATTERY q ...

Страница 2: ...ications BATTERY CHARGER FEATURES Completely automatic operation charges battery on demand Output Voltage regulated eliminates overcharging battery Output Voltage temperature compensated optional Output current limited to protect charger from overloading A 5 LED display indicating charge state and faults Reverse polarity protection INSTALLATION The AUTO CHARGEd ODY should be installed in an area w...

Страница 3: ...e and the green indicator labeled Battery Charged AND red indicator labeled Time Out will be illuminated Figure 1 depicts the above described operation Note that the term absorption charge is used interchangeably with finish charge Upon application of AC power the charger is placed into bulk charge if necessary When the charger switches to finish charge a timer starts This timer has a duration of ...

Страница 4: ...oltage Increasing Current Constant Voltage Constant Current Decreasing Voltage Constant Full Charge Maintained STAGE I CONSTANT CURRENT BULK STAGE II CONSTANT VOLTAGE ABSORPTION STAGE III CONSTANT VOLTAGE FLOAT TIME Figure 1 14 70VDC 13 60VDC I Limit 40 0A 8 0 Hours Model 091 128 12E 40 115 ...

Страница 5: ......

Страница 6: ... Output Power 12 to 14 7VDC 40Amperes Current Limited Charge Indicator 50Amperes Mode Indicators Battery Fault Red TimeOut Red Bulk Charge Yellow Finish Charge Yellow Battery Charged Green Recommended Battery Size Odyssey AGM Series PC 150 to 300 AH Weight 28 Pounds Temperature Compensation Optional not used on this model ...

Страница 7: ......

Страница 8: ...14 0 9 31 9 25 Figure 3 OUTLINE DRAWING ...

Страница 9: ...y material or defects which become apparent in normal use within 3 years from the date the equipment was shipped Kussmaul Electronics Company Inc shall have no liability for dam ages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The pur chaser by the acceptance of the equipment assumes all liability for any damages whi...

Отзывы: