14)        key :- By pressing this key for once, the backlight
      of  the  LCD  screen  will  be  turn  ON  and  after  60 
      seconds  the  meter  will  automatically  turn  off  the 
      backlight. It is also possible to turn off the backlight by 
    pressing  this  key  before  the  60  seconds.

5)  

CAL 

key :- Used to do OPEN/SHORT calibration.

6) 

SORTING 

key  :-  Press  this  key  to  enter  into 

     sorting mode, which could help the user to make 
     a quick sort for a bunch of components.

7)  

PC LINK 

key :- Press this key to communicate 

     with PC.

8)  

HOLD 

key :- Used to maintain the measurement 

     data unchanging, by pressing the key again it will 
     resume the measurement.

9)  

D/Q/ESR 

key :- In L/C measurement mode, 

     press the key to select parameters of D/Q/

q

/ESR.

10) 

SETUP 

key :- When sorting mode is active, press 

      

SETUP 

key to modify the reference value, range 

      and the tolerance setting sequentially.

11) 

SER/PAL 

key :- Used to select series and 

      parallel mode.

12) 

FREQ 

key :- Press 

FREQ

 key to select five 

      different test frequencies in turn : 100/120/1K/
      10K/100KHz

13) 

REL% 

key  :-  Press 

REL% 

key  to  enter  into 

      relative measurement mode. In auto LCR mode, 
      this key is not available.

8

The instrument has 4-terminal measurement 
configuration, as shown in figure 2.

GUARD

GUARD

INPUT

Rx Lx Cx

L

Grounding (shielding)

Excitation positive 

terminal

Measurement positive terminal
Measurement negative terminal
Excitation negative terminal

Figure-2

Understanding Display Screen

Figure-3

CUR

L

POT

H

POT

H

CUR

15) 

ENTER 

key :- In sorting mode, press 

ENTER 

key 

      to confirm the data modification.

16) Measurement terminal 

LCD screen is shown as in Figure 3, with its every 
symbol's meaning shown as in the Table 1:

Содержание KM 520B

Страница 1: ...meter Wood Paper Grain Moisture Meter Distance Meter Network Cable Tester Digital Hand Held Temperature Indicators Digital Lux Meter Thermal Imaging Camera Power Factor Regulator Maximum Demand Contro...

Страница 2: ...o turn off the instrument when replacing the battery or DC power adapter Although the instrument has a protection for shocks inputing dc voltage or current will still damage the instrument The capacit...

Страница 3: ...20nF 20mF 2000pF 2mF 200pF 200m F 200pF 20m F 200W 200MW 20W 200MW 20W 20MW 20W 2MW C R DCR D Q q Test Level Range mode Equivalent circuit 0 6 Vrms Auto and Hold Parallel and Series 4 Specifications C...

Страница 4: ...ity factor ESR equivalent series resistance Rp equivalent series parallel resistance q phase angle 6 Explanation on Front Panel The front panel is shown as figure 1 1 Mini USB interface Connect with P...

Страница 5: ...y When sorting mode is active press SETUP key to modify the reference value range and the tolerance setting sequentially 11 SER PAL key Used to select series and parallel mode 12 FREQ key Press FREQ k...

Страница 6: ...ay is quality factor Q C D Capacitance measurement the parameter on sub display is dissipation factor D R Resistance measurement DCR DC resistance measurement mode L C R measurement readings can be po...

Страница 7: ...bers the current readings on primary display called initial value when pressing the REL key and 12 b When using insert the black and red testing lines with alligator clip into the terminal and termina...

Страница 8: ...gs to the component type press FUNC key to select L C or R measurement mode 2 Insert the standard component into the input therminal Press SORTING key to enter into the sorting mode and the Sorting sy...

Страница 9: ...nce setting mode automatically 6 When setting the tolerance press D Q ESR key SER PAL key to select tolerance range 0 25 0 5 1 2 5 10 20 80 20 The default tolerance is 1 Press ENTER key to confirm 16...

Страница 10: ...x Lx Cx LCUR LPOT HPOT HCUR GUARD GUARD INPUT Rx Lx Cx LCUR LPOT HPOT HCUR Figure 8 Figure 9 18 4 The default test mode is Auto LCR mode the capacitance value will be shown on primary display and the...

Страница 11: ...ilable 3 The default test mode is Auto LCR mode the resistance value will be shown on primary display and the phase angle q will be shown on secondary display In Auto LCR mode the D Q ESR key SEL PAL...

Страница 12: ...t and then firmly insert DC plug into DC input end in the right of the meter When unplugged firstly pull out the DC plug perpendicular to DC input end and then unplug the AC plug from the electrical o...

Страница 13: ...s warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at...

Отзывы: