Thank  you  for  purchasing  the  multi-function  LCR 

meter. Please take a few minutes to browse through 

this  user  manual  before  you  begin  to  operate  the 

meter to ensure that you are fully familiarized with 

how  best  to  operate  the  meter  as  accurately  and 

safely as possible.

Overview

This  multi-function  LCR  meter  is  a  portable 

instrument  designed  with  microprocessor  control 

and low power consumption. It can measure 6 basic

parameters:  inductance  L,  capacitance  C,  AC 

resistance R, DC resistance  DCR, dissipation factor

D and quality factor

With  battery  external  power  supply,  the  meter  is 

ideal  for  field  and  portable  applications,  such  as 

component inspection at fixed place, and immediate 

measurement by maintenance personnel.

Q. The instrument can easily communicate with PC 

and realize remote control through USB interface.

Cautions

=

 

This instrument can only be used in indoor.

=

 

Be sure to turn off the instrument when replacing 

     the  battery or DC power adapter.

=

 

Although the instrument has a protection for shocks,

      inputing  dc  voltage  or  current  will  still  damage  the 

    instrument.  The  capacitance  requires  completely

    discharge before measuring.

2

=

  In  order  to  ensure  the  measurement  accuracy, 

    open / short calibration should be carried out again 

    after replacing the test fixtures.

=

 If  the  instrument  is  idle  for  more  than  15 days 

     please  take  the  batteries  out.

=

  Use  AAA  *  6  batteries.  The  instrument  can  not 

     work properly when low battery voltage indication 

     appears.

=

 Do not using the instrument under dusty, vibration,

    direct sunlight and corrosion gas. environment

Introduction

Features

=

 19,999/1,999 counts dual LCD display

=

 Basic accuracy : 0.3% with resolution of 0.01%

=

 Analog bar display

=

 Measurement frequency up to 100KHz

=

 Mini-USB interface 

=

 Auto LCR smart check and measurement

=

 Sorting function

=

 Relative measurement

=

 Data hold,

=

 Back light, full angle for LCD display

=

 4-terminal measurement configuration

=

 Automatic power off

=

 Battery and external power supply

=

 Battery voltage indication.

Содержание KM 520B

Страница 1: ...meter Wood Paper Grain Moisture Meter Distance Meter Network Cable Tester Digital Hand Held Temperature Indicators Digital Lux Meter Thermal Imaging Camera Power Factor Regulator Maximum Demand Contro...

Страница 2: ...o turn off the instrument when replacing the battery or DC power adapter Although the instrument has a protection for shocks inputing dc voltage or current will still damage the instrument The capacit...

Страница 3: ...20nF 20mF 2000pF 2mF 200pF 200m F 200pF 20m F 200W 200MW 20W 200MW 20W 20MW 20W 2MW C R DCR D Q q Test Level Range mode Equivalent circuit 0 6 Vrms Auto and Hold Parallel and Series 4 Specifications C...

Страница 4: ...ity factor ESR equivalent series resistance Rp equivalent series parallel resistance q phase angle 6 Explanation on Front Panel The front panel is shown as figure 1 1 Mini USB interface Connect with P...

Страница 5: ...y When sorting mode is active press SETUP key to modify the reference value range and the tolerance setting sequentially 11 SER PAL key Used to select series and parallel mode 12 FREQ key Press FREQ k...

Страница 6: ...ay is quality factor Q C D Capacitance measurement the parameter on sub display is dissipation factor D R Resistance measurement DCR DC resistance measurement mode L C R measurement readings can be po...

Страница 7: ...bers the current readings on primary display called initial value when pressing the REL key and 12 b When using insert the black and red testing lines with alligator clip into the terminal and termina...

Страница 8: ...gs to the component type press FUNC key to select L C or R measurement mode 2 Insert the standard component into the input therminal Press SORTING key to enter into the sorting mode and the Sorting sy...

Страница 9: ...nce setting mode automatically 6 When setting the tolerance press D Q ESR key SER PAL key to select tolerance range 0 25 0 5 1 2 5 10 20 80 20 The default tolerance is 1 Press ENTER key to confirm 16...

Страница 10: ...x Lx Cx LCUR LPOT HPOT HCUR GUARD GUARD INPUT Rx Lx Cx LCUR LPOT HPOT HCUR Figure 8 Figure 9 18 4 The default test mode is Auto LCR mode the capacitance value will be shown on primary display and the...

Страница 11: ...ilable 3 The default test mode is Auto LCR mode the resistance value will be shown on primary display and the phase angle q will be shown on secondary display In Auto LCR mode the D Q ESR key SEL PAL...

Страница 12: ...t and then firmly insert DC plug into DC input end in the right of the meter When unplugged firstly pull out the DC plug perpendicular to DC input end and then unplug the AC plug from the electrical o...

Страница 13: ...s warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at...

Отзывы: