33
3BA00205 • 2020-10-28 • Rev. 5
Ersa i-CON
VARIO 2
Functional description
6.4
Configuration mode
To enter the configuration mode press and hold the i‑OP for 2 seconds when switching on the i‑CON
VARIO 2.
By turning and pressing the whole station can be configured or reset to factory settings.
In configuration mode the following settings can be adapted for the station:
•
Temperature window (monitoring) left and right tool socket
• Process alarm (audible temp. control)
•
Idle state (shut‑down function)
• Password
• Temperature unit
•
Activating the heating plate
•
Language selection for the station
• VAC PEN Mode
With active password protection you cannot reset the soldering station to the
“as delivered” state (default) without entering the password.
6.4.1
Temperature window
For each tool socket a temperature window with a separate upper and
lower range can be defined.
When the actual temperature is within this window, “OK” is displayed in
working mode.
Factory setting:
↑ 20 °C
↓ 20 °C (± 20 °C (68 °F)).
For the soldering tool connected to tool socket A1 the bottom line shows the symbol
[
◄
]. For the soldering tool connected to tool socket A2 the bottom line shows the
symbol [
►
]. Keep turning the i‑OP, until the temperature window indicates the desired
socket.