21
GB
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-
pole switch having a contact gap of at least 3
mm.
• Remove the grease filters (see paragraph
Maintenance) being sure that the connector of
the feeding cable is correctly inserted in the socket
placed on the side of the fan.
• Connect the control connector Cmd.
• Connect the lights connector Lux.
• Place the connectors in the junction box 24 and
close it using the 2 screws 12e (2,9 x 9,5)
provided.
• Fix the junction box to the hood body using the
2 screws 12c (2,9 x 6,5) provided.
• For the recirculation version, fit the activated
carbon odour filter.
• Replace the grease filters.
USE
Control Panel
The hood can be switched on pushing directly onto the requested speed without firstly having to
select 0/1 button.
KEY
LED
FUNCTIONS
L
0/1 Light
Turns lighting on and off.
T1
0/1 Motor
on
First speed.
When pressed for about 2 seconds the motor is switched
off.
T2
Speed
on
Second speed.
T3
Speed
on
Third speed.
T4
Speed
Fixed
Max. speed
Flashing
Intensive speed.
Suitable for the strongest cooking vapours and odours.
The function becomes active when the button is pushed
for about 2 seconds. After 10 minutes of functioning it
turns off automatically. This function can be interrupted
by means of pressing any of the buttons.
24
12e
Cmd
12c
Lux
2
3
4
I
F
L
S1
T1
T2
T3
T4