background image

8

Service Manual

For internal use only

4.

Controls

 

Key 

Function 

Display 

Switches the extractor motor on and off. 

-

Reduces the operating speed. 

The illuminated segments are reduced. 

Increases the operating speed. 

The illuminated segments are 
increased. 

Activates the intensive speed, apart from the 
delay and 24 h speeds, 

which

 is timed for ten 

minutes. When this time has expired, the 
system returns to the speed that had previously 
been set. Suitable for removing extremely 
intensive cooking odours. 

blinks and all the segments on the 

display light up. 

Is switched off by pressing the key. 

The alarm for the charcoal filter is activated / 
deactivated keeping the key pressed for approx. 
5 seconds with the consumers (motor + light) 
switched off. 

Symbol C blinks twice – alarm 
activated.
Symbol C blinks once – alarm 
deactivated.

Activates the motor in the 

air circulation

 mode, 

at a speed which enables an extraction rate of 
100 m³/h for 10 minutes every hour, after which 
time the motor is stopped. 

Shows 

24

, and all the segments shown 

on the display are deleted one after the 
other. 
Is switched off by pressing the key.

F

• Activates  the  automatic  switch-off  function

with a 30-minute delay. 

• Completes the removal of residual odours. 
• Can  only  be  activated  when  the  motor  is

switched  on  at  a  speed  that  is  not  24H  or
intensive speed. 

Shows a flashing clock as a symbol. 

Is switched off by pressing the key. 

Keep the key pressed for approx. 5 seconds to 
switch the remote control on and off. 

When the horizontal bar blinks twice - 
remote control activated. 
When the horizontal bar blinks once - 
remote control deactivated. 

Resets the filter saturation alarm when the key 
is pressed for approx. 3 seconds. 

After 100 hours of operation the 

drop 

symbol

 shows that the metal filters are 

saturated. 
After 200 hours of operation the 

C

 

shows that the charcoal filters are 
saturated. 

Содержание KD6590.0GE

Страница 1: ...Cooker hoods KD6590 0GE and KD9590 0GE Accessing the components...

Страница 2: ...Manual H5 85 04 Responsible U Laarmann K PPERSBUSCH HAUSGER TE AG E mail uwe laarmann kueppersbusch de Tel 0209 401 732 Customer Service Fax 0209 401 743 Postfach 100 132 Date 18 06 2013 45801 Gelsen...

Страница 3: ...g the components inside the hood 5 2 1 Removing the controls 5 2 2 Accessing the electronic unit and the transformer 6 2 3 Accessing the halogen lamp 6 3 Circuit diagram 7 4 Controls 8 5 Filters 10 5...

Страница 4: ...l current circuit breaker must always be used The earthed conductor resistance may not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functionin...

Страница 5: ...ls can be opened when pulled out This gives you access to the components inside the hood The panel is removed by means of the movable hinge peg 2 1 Removing the controls 1 Remove the two screws that f...

Страница 6: ...nside the hood can be accessed The ATF circuit board and the transformer of appliances fitted with an Athena electronic system are located in a box within the Easy Cube 2 3 Accessing the halogen lamp...

Страница 7: ...Service Manual 7 For internal use only 3 Circuit diagram...

Страница 8: ...ates the motor in the air circulation mode at a speed which enables an extraction rate of 100 m h for 10 minutes every hour after which time the motor is stopped Shows 24 and all the segments shown on...

Страница 9: ...ep key A pressed for approx 5 seconds in order to activate or deactivate the keyboard lock The procedure is always confirmed with a beep and when the motor bar is shown on the display H Reduces the in...

Страница 10: ...ecome discoloured with time this will not have any impact on the effectiveness of a filter 4 When remounting the filters make sure that the handle is on the visible exterior 5 Close the Comfort Panel...

Страница 11: ...e the alarm for the charcoal filter setting is DEACTIVATED 5 2 2 Replacing the charcoal odour filter Resetting the saturation display 1 Switch off the lighting and the fan motor 2 Press key G for at l...