8
Service Manual
For internal use only
4.
Controls
Key
Function
Display
A
Switches the extractor motor on and off.
-
B
Reduces the operating speed.
The illuminated segments are reduced.
C
Increases the operating speed.
The illuminated segments are
increased.
D
Activates the intensive speed, apart from the
delay and 24 h speeds,
which
is timed for ten
minutes. When this time has expired, the
system returns to the speed that had previously
been set. Suitable for removing extremely
intensive cooking odours.
I
blinks and all the segments on the
display light up.
Is switched off by pressing the key.
The alarm for the charcoal filter is activated /
deactivated keeping the key pressed for approx.
5 seconds with the consumers (motor + light)
switched off.
Symbol C blinks twice – alarm
activated.
Symbol C blinks once – alarm
deactivated.
E
Activates the motor in the
air circulation
mode,
at a speed which enables an extraction rate of
100 m³/h for 10 minutes every hour, after which
time the motor is stopped.
Shows
24
, and all the segments shown
on the display are deleted one after the
other.
Is switched off by pressing the key.
F
• Activates the automatic switch-off function
with a 30-minute delay.
• Completes the removal of residual odours.
• Can only be activated when the motor is
switched on at a speed that is not 24H or
intensive speed.
Shows a flashing clock as a symbol.
Is switched off by pressing the key.
Keep the key pressed for approx. 5 seconds to
switch the remote control on and off.
When the horizontal bar blinks twice -
remote control activated.
When the horizontal bar blinks once -
remote control deactivated.
G
Resets the filter saturation alarm when the key
is pressed for approx. 3 seconds.
After 100 hours of operation the
drop
symbol
shows that the metal filters are
saturated.
After 200 hours of operation the
C
shows that the charcoal filters are
saturated.