background image

4

Service Manual

For internal use only

1.

Safety

Danger!

Repairs may only be carried out by a qualified electrician! 

Improper repairs can be extremely dangerous for the user.

It is essential that you observe the following instructions in order to prevent electric shocks:

The casing and the frame may be live in the event of faults!

Touching live components inside the appliance may cause dangerous currents to flow through your

body!

Disconnect the appliance from the mains prior to carrying out any repair work!

When inspecting live parts, a residual current circuit breaker must always be used!

The earthed conductor resistance may not exceed the resistance specified in the standard! It is vital

for ensuring the safety of persons and the functioning of the appliance.

On  completion  of  repairs,  an  inspection  must  be  carried  out  in  accordance  with  VDE  0701

[Association of German Electrical Engineers] or the corresponding regulations for your country!

It is essential that you observe the following instructions:

The  appliances  must  be  disconnected  from  the  mains  prior  to  all  repairs.  If  inspections  must  be

carried out on live appliances, make sure you use a residual current circuit breaker. 

Attention!

Sharp edges: use protective gloves.

Components may be electrostatic!

Observe handling regulations!

Содержание KD6590.0GE

Страница 1: ...Cooker hoods KD6590 0GE and KD9590 0GE Accessing the components...

Страница 2: ...Manual H5 85 04 Responsible U Laarmann K PPERSBUSCH HAUSGER TE AG E mail uwe laarmann kueppersbusch de Tel 0209 401 732 Customer Service Fax 0209 401 743 Postfach 100 132 Date 18 06 2013 45801 Gelsen...

Страница 3: ...g the components inside the hood 5 2 1 Removing the controls 5 2 2 Accessing the electronic unit and the transformer 6 2 3 Accessing the halogen lamp 6 3 Circuit diagram 7 4 Controls 8 5 Filters 10 5...

Страница 4: ...l current circuit breaker must always be used The earthed conductor resistance may not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functionin...

Страница 5: ...ls can be opened when pulled out This gives you access to the components inside the hood The panel is removed by means of the movable hinge peg 2 1 Removing the controls 1 Remove the two screws that f...

Страница 6: ...nside the hood can be accessed The ATF circuit board and the transformer of appliances fitted with an Athena electronic system are located in a box within the Easy Cube 2 3 Accessing the halogen lamp...

Страница 7: ...Service Manual 7 For internal use only 3 Circuit diagram...

Страница 8: ...ates the motor in the air circulation mode at a speed which enables an extraction rate of 100 m h for 10 minutes every hour after which time the motor is stopped Shows 24 and all the segments shown on...

Страница 9: ...ep key A pressed for approx 5 seconds in order to activate or deactivate the keyboard lock The procedure is always confirmed with a beep and when the motor bar is shown on the display H Reduces the in...

Страница 10: ...ecome discoloured with time this will not have any impact on the effectiveness of a filter 4 When remounting the filters make sure that the handle is on the visible exterior 5 Close the Comfort Panel...

Страница 11: ...e the alarm for the charcoal filter setting is DEACTIVATED 5 2 2 Replacing the charcoal odour filter Resetting the saturation display 1 Switch off the lighting and the fan motor 2 Press key G for at l...

Отзывы: