5.

Filters

5.1

Metal grease filters

The filters can be cleaned in the dishwasher; they should be cleaned when the drop symbol appears on
the  display,  or  at  least  approx.  every  2  months,  or  more  frequently  when  the  hood  is  used  very
intensively.

5.1.1

Resetting the saturation display

Press key G for at least 2 seconds.

5.1.2

Cleaning the filters

1.

Open the Comfort Panel.

2.

Remove the filters one by one by pushing them to the back of the
group and at the same time pulling them down.

3.

Wash  the  filters,  making  sure  not  to  bend  them,  and  dry  them
before putting them back in place (the filter surfaces may become
discoloured  with  time;  this  will  not  have  any  impact  on  the
effectiveness of a filter).

4.

When remounting the filters,  make  sure that the handle  is on the
visible exterior.

5.

Close the Comfort Panel again.

IMPORTANT: For the 60-cm model, only remove the filters one after 
the other by initially pushing them backwards while at the same 
time pulling them downwards and then pulling them towards the 
centre of the hob.

5.2

Charcoal odour filter (filter version)

The  charcoal  filter  is  not  washable  and  nor  is  it  recoverable;  it  needs  to  be  replaced  as  soon  as  the
symbol C is shown in the display or at least after 4 months. The alarm report is preventively activated.

5.2.1

Activating the alarm signal

1.

For  cooker  hoods  with  filters,  the  alarm  display  for  filter  saturation  is  activated  when  the  filter  is
installed or as a result of installation.

Содержание KD6590.0GE

Страница 1: ...Cooker hoods KD6590 0GE and KD9590 0GE Accessing the components...

Страница 2: ...Manual H5 85 04 Responsible U Laarmann K PPERSBUSCH HAUSGER TE AG E mail uwe laarmann kueppersbusch de Tel 0209 401 732 Customer Service Fax 0209 401 743 Postfach 100 132 Date 18 06 2013 45801 Gelsen...

Страница 3: ...g the components inside the hood 5 2 1 Removing the controls 5 2 2 Accessing the electronic unit and the transformer 6 2 3 Accessing the halogen lamp 6 3 Circuit diagram 7 4 Controls 8 5 Filters 10 5...

Страница 4: ...l current circuit breaker must always be used The earthed conductor resistance may not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functionin...

Страница 5: ...ls can be opened when pulled out This gives you access to the components inside the hood The panel is removed by means of the movable hinge peg 2 1 Removing the controls 1 Remove the two screws that f...

Страница 6: ...nside the hood can be accessed The ATF circuit board and the transformer of appliances fitted with an Athena electronic system are located in a box within the Easy Cube 2 3 Accessing the halogen lamp...

Страница 7: ...Service Manual 7 For internal use only 3 Circuit diagram...

Страница 8: ...ates the motor in the air circulation mode at a speed which enables an extraction rate of 100 m h for 10 minutes every hour after which time the motor is stopped Shows 24 and all the segments shown on...

Страница 9: ...ep key A pressed for approx 5 seconds in order to activate or deactivate the keyboard lock The procedure is always confirmed with a beep and when the motor bar is shown on the display H Reduces the in...

Страница 10: ...ecome discoloured with time this will not have any impact on the effectiveness of a filter 4 When remounting the filters make sure that the handle is on the visible exterior 5 Close the Comfort Panel...

Страница 11: ...e the alarm for the charcoal filter setting is DEACTIVATED 5 2 2 Replacing the charcoal odour filter Resetting the saturation display 1 Switch off the lighting and the fan motor 2 Press key G for at l...

Отзывы: