28
H5-60-85-01
For internal use only
6.
Insert the top part of the hood
into the bottom part and fasten it onto the supporting plate
with
the 4x8 screws.
Recirculating air operation
The recirculating air diverter is screwed to the wall bracket, (fig. 2).
•
Connect the recirculation air casing (which is the same color as the hood and is provided with a
ventilation opening) to the recirculating airdiverter.
•
Connect the connection pipe of the respective diameter to the opening of the recirculating air
diverter and the output opening of the fan.
•
Connect the diagonal connection pieces supplied to the inner edges of the frame in accordance
with the diagram, using the 4.2 x 9.5 screws.
•
Insert the charcoal filter cartridge from the bottom into the respective frame of the casing of the
hood, and engage by means of the shaped bracket (A) (Fig. 4).