H5-60-85-01
7
For internal use only
2.
The high-power setting is activated by means of pressing LED 5 (Max.) once. The fan is automati-
cally switched back to the previously-set power level when the “5 minutes follow-up time“ of the
high-power setting has elapsed.
3.
The high-power setting is switched off by means of activating LED 5 (Max.) once again.
Attention: This function cannot be carried out if the
“
automatic switch-off for the follow-up
time of the fan
“
has been activated.
3.3
Automatic switch-off device for the fan follow-up time
This function enables any remaining cooking steam to be extracted by means of time-limited extraction
(follow-up time) subsequent to the actual cooking process, after which the fan and the lamps are
switched off automatically.
The lamp and the motor must be switched off at the controls in order to program this function. The cooker
hood, however, must be connected to the mains. Pressing switch no. 5 (INT) once or several times will
adjust the follow-up time as follows:
•
1 blink of the LEDs 1 and 5 indicates the "Off" function.
•
2 blinks of the LEDs 1 and 5 indicate "5 minutes follow-up time".
•
3 blinks of the LEDs 1 and 5 indicate "10 minutes follow-up time".
•
4 blinks of the LEDs 1 and 5 indicate "15 minutes follow-up time".
Please switch on the appliance once it has been progammed. Set the required fan power level. The
follow-up time programmed will be indicated by the blinking of LEDs 2, 3 and 4 as follows:
In the case of the MAX. setting
•
LEDs 2, 3 and 4 do not blink if the "automatic switch-off " function has not been activated.
•
LEDs 2, 3 and 4 blink once if a follow-up time of "5 minutes" has been programmed.
•
LEDs 2, 3 and 4 blink twice if a follow-up time of "10 minutes" has been programmed.
•
LEDs 2, 3 and 4 blink three times if a follow-up time of "15 minutes" has been programmed.
In the case of the MED. setting
•
LEDs 2, 3 and 4 do not blink if the "automatic switch-off” function has not been activated.
•
LEDs 2 and 3 blink once if a follow-up time of "5 minutes" has been programmed.
•
LEDs 2 and 3 blink twice if a follow-up time of "10 minutes" has been programmed.
•
LEDs 2 and 3 blink three times if a follow-up time of "15 minutes" has been programmed.
In the case of the MIN. setting
•
LEDs 2, 3 and 4 do not blink if the "automatic switch-off” function has not been activated.
•
LED 2 blinks once if a follow-up time of "5 minutes" has been programmed.
•
LED 2 blinks twice if a follow-up time of "10 minutes" has been programmed.
•
LED 2 blinks three times if a follow-up time of "15 minutes" has been programmed.