background image

FOR PWD14 EUROPA VENT-A-HOODS

INSTALLATION INSTRUCTIONS

A. Installation Work and Electrical Wiring Must Be Done By

Qualified Person(s) In Accordance With All Applicable

Codes And Standards, Including Fire-Rated Construction.

B. When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

C. Ducted fans must always be vented to the out-

doors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

D. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel

burning equipment to prevent back drafting. Follow the

heating equipment manufacturer’s guideline and safety

standards such as those published by the NationaI Fire

Protection Association (NFPA), and the American Society

for Heating, Refrigeration and Air Conditioning Engineers

(ASHRAE), and local code authorities.

Read and Save These Instructions

Turn Page For More Instructions

All Hoods Should Be Installed By A Qualified Installer

CEILING

Step 2 . . .

Remove wood strip from rear of

hood and secure to the wall at

proper mounting height. Bottom of

hood should be 24” to 27” from

cooking surface.

Step 3 . . .

Install duct work on top

of hood. Make sure

length is sufficient to

connect to duct work in

ceiling.

Step 1 . . .

Remove hood and duct

cover from wood pallet and

set on a protected surface.

Step 5 . . .

Lift fully assembled unit to wall and hang hood on wood strip.

Secure hood to wall with proper fasteners. You may have to drill

new mounting holes in back of hood to line up with studs. The

“crimped” end of the duct pipe should be facing towards ceiling

as you lift hood into position. The back of the duct cover should

lay flat against the wall and does not generally need to be

secured at the top.

DUCT

COVER

WOOD STRIP

BACK

VIEW

DUCT PIPE

LIFT HOOD, DUCT PIPE, AND DUCT

COVER UP TO MOUNTING LOCATION

AS ONE UNIT

BACK

VIEW

DUCT

DUCT PIPE

COVER

DUCT

COVER

Step 4 . . .

Install duct cover to top

of hood with bolts

provided.

WIRING

Отзывы: