background image

Page 1

L124 0516A

UL

C

US

R

Read and Save These Instructions 

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS 

AH12 WALL MOUNT HOOD

Read All Instructions Thoroughly Before Beginning Installation

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) 

in accordance with all applicable codes and standards, including fire-

rated construction. Switch power off at service panel and lock the service 

disconnecting means to prevent power from being switched on accidentally 

during installation.

B.  When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

C. Ducted fans must always be vented to the outdoors.

D. Sufficient air is needed for proper combustion and exhausting of gases 

through the flue (chimney) of fuel burning equipment to prevent back 

drafting.  Follow  the  heating  equipment  manufacturer’s  guideline  and 

safety standards such as those published by the National Fire Protection 

Association (NFPA), and the American Society for Heating, Refrigeration 

and Air Conditioning Engineers (ASHRAE), and local code authorities.

E.  ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to 

a maximum of 15 CFM per 100 square feet of occupiable space, unless a 

back drafting test is performed or make-up air is provided. Consult a local 

HVAC engineer for make-up air evaluation.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK

Содержание AH12

Страница 1: ...o wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Pr...

Страница 2: ...rements and placement of duct against combustibles Make the duct run as short and as straight as possible with as few turns as possible Avoid sharp angled turns Instead use smooth gradual turns such as adjustable elbows or 45 degree angled turns For duct runs over 20 feet increase the duct diameter by one inch for every ten feet of duct A 90 degree elbow is equal to 5 feet of duct Using Vent A Hoo...

Страница 3: ...Consult the connection diagram on next page for further details on exhaust outlet placement Use duct tape to seal all joints A complete listing of available Vent A Hood ducting materials is provided on the back page of this instruction sheet 4 Place the ceiling collar on the ceiling with the notched side 1 16 from the wall Center the ceiling collar over the location where the hood will hang Trace ...

Страница 4: ...an shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tipped to clear the blower wheel s and then out of the hood 7 Remove the three scre...

Страница 5: ...to ensure that the electrical wire does not get pinched Secure the hood to the wood mounting strip by installing the screws previously removed from the strip in Step 10 into the pilot holes drilled in Step 11 14 From inside the hood using UL listed wire nuts attach the neutral wire to the white lead inside the motor box the hot wire to the black lead inside the motor box and the ground wire to the...

Страница 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...