background image

3

GB

READ AND SAVE THESE INSTRUCTIONS

The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future reference and for local electrical
inspectors’ use.
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD

WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave
surface units unattended at high settings. Boilovers cause smoking and greasy spillovers
that may ignite. Heat oils slowly on low or medium setting.  Always turn hood ON when
cooking at high heat or when flambeing foods (i.e. Crepes Suzette, Cherries Jubilee, Pep-
percorn Beef Flambè). Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the
size of the surface element.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES
 with a
close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS
. If the flames do not go out immediately EVACUATE AND CALL THE FIRE
DEPARTMENT. NEVER PICK UP A FLAMING PAN
 - You may be burned. DO NOT USE
WATER
, including wet dishcloths or towels - a violent steam explosion will result. Use an
extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you already know
how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire
department is being called. 4. You can fight the fire with your back to an exit.

ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE
SEALED.

This rangehood requires at least 24" of clearance between the bottom of the rangehood and
the cooking surface or countertop. This minimum clearance may be higher depending on
local building code. For example, for gas ranges, a minimum of 30" may be required. The
maximum depth of overhead cabinets is 13". Overhead cabinets on both sides of this unit
must be a minimum of 18" above the cooking surface or countertop. Consult the cooktop or
range installation instructions given by the manufacturer before making any cutouts. MOBILE
HOME INSTALLATION. The installation of this rangehood must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Stan-
dard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). Four wire power
supply must be used and the appliance wiring must be revised. See Electrical Requirements.

VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either
through the wall or the roof. The length of the ductwork and the number of elbows should
be kept to a minimum to provide efficient performance. The size of the ductwork should be
uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork
system. Use caulking to seal exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. Flexible ductwork creates back pressure
and air turbulence that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making
cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut,
then a supporting frame must be constructed

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

Содержание IKD 12250.0

Страница 1: ...IKD 12250 0 Instructions Booklet Mode d emploi FR GB...

Страница 2: ......

Страница 3: ...NSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop This minimum clearance may be higher depending on loc...

Страница 4: ...d disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary A UL Listed 1 2...

Страница 5: ...ioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the...

Страница 6: ...6 GB CHARACTERISTICS Dimensions 650 min 698 120 898 min 861 max 1146 696 350 150 90 306 130 290 20...

Страница 7: ...utletGrill 8b 1 LeftAirOutletGrill 14 1 1 AirOutletConnectionExtension 15 1 AirOutletConnection 24 1 Junctionbox 25 2 Pipeclamps Ref Q ty Installation Components 11 4 WallPlugs 10 12c 6 Screws 2 9 x 9...

Страница 8: ...ilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power sup...

Страница 9: ...e mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame...

Страница 10: ...l symbols are towards the top Also make sure that they are correctly inserted in the connection extension pieces 14 1 Before fixing the hood body to the frame Remove the grease filters from the hood b...

Страница 11: ...evel ratio V3 Speed Maximumspeed usedforeliminatingthehighestcookingvapouremission including long periods MAINTENANCE Grease filters CLEANING METAL SELF SUPPORTING GREASE FILTERS The filters must be c...

Страница 12: ...al grease filters Lighting LIGHT REPLACEMENT 20 W halogen light Remove the 2 Screws fixing the Lighting sup port and pull it out of from the Hood Extract the Lamp from the Support Replace with another...

Страница 13: ...MIT DE LA HOTTE DOIT TRE SCELL Gardez 24 po de hauteur entre le bas de la hotte et la surface de cuisson Cette hauteur minimum peut tre plus haute suivant le code municipal Par exemple les cuisini res...

Страница 14: ...all chaque bout de fil soit l appareil ainsi qu la boite fusible Faites un trou de 1 1 4 po dans le mur S il s agit d un trou en bois sablez le bien tandis qu un trou passant par le m tal demande un b...

Страница 15: ...rforer un autre fil lectrique Une hotte vacuation ext rieure doit tre raccord e l ext rieur Une prise terre est n cessaire pout cette hotte N utilisez pas un tuyau l eau froide pour la mise terre s il...

Страница 16: ...16 FR CARACTERISTIQUES Encombrement 650 min 698 120 898 min 861 max 1146 696 350 150 90 306 130 290 20...

Страница 17: ...oite SortieAir 8b 1 Grille en Direction Gauche SortieAir 14 1 1 Rallonge Raccord SortieAir 15 1 Raccord SortieAir 24 1 Bo teconnexions 25 2 Colliers de serrage serre tube R f Q t Composants pour l ins...

Страница 18: ...ec paisseur r sistante de 20 mm 10 mm ins rer imm diatement les Chevilles 11 fournies avec l appareil Plafond en Poutrage en Bois en fonction des Vis Bois utilis es tag re en Bois 7 mm Passage du C bl...

Страница 19: ...oit tre solide en fonction du poids de la Hotte et des contraintes provoqu es par les pouss es lat rales occasionnelles auxquelles l Appareil mont sera soumis Apr s avoir effectu la fixation v rifier...

Страница 20: ...orient s vers le haut S assurer galement qu elles sont bien ins r es dans les rallonges raccord 14 1 Avant de fixer le Corps de la Hotte au Treillis Retirer les Filtres anti graisse du Corps de la Hot...

Страница 21: ...niveau sonore V3 Vitesse Vitesse maximum pour faire face aux missions maximum de vapeur de cuisson m me pendant des temps prolong s ENTRETIEN Filtres anti graisse NETTOYAGE FILTRES ANTI GRAISSE METALL...

Страница 22: ...Eclairage REMPLACEMENT LAMPES Lampe halog ne de 20 W Retirer les 2Vis qui fixent le Support clairage et ter ce dernier de la Hotte Extraire la Lampe du Support Remplacer par une nouvelle lampe poss d...

Страница 23: ......

Страница 24: ...ERSBUSCH Hausger te AG K ppersbuschstra e 16 D 45883 Gelsenkirchen Hausanschritt K ppersbuschstr 16 45883 Gelsenkirchen Telefon 02 09 4 01 0 Telefax 20 931 810 Telefax 02 09 4 01 3 03 436002169_02 040...

Отзывы: