Dismantling and installation of the activated charcoal filters
After dismantling the grease filters attach the active charcoal filters to the aspiration hole of the motor.
To do so, adjust the Bayonett fitting on the motor casing and turn the filters in order to fasten them as
shown in the illustration.
7.
Installing the recirculating air diverter
In the case of the recirculating air mode, a recirculating air
diverter must be installed so that the cooking fumes extracted
can escape through the ventilation openings on the side of the
upper chimney.
Subsequent to installing the upper chimney mounting support
(A), attach the recirculating air diverter (B) with screws as
shown in the illustration.
Then connect the recirculating air diverter to a pipe (diameter
of 150 mm) and to the motor outlet. Hose clips should be used
for connecting.