Wiring diagrams

KD 957.1

Содержание IKD 1157.1

Страница 1: ... D y y ac IIMOFI D c QMOFI ...

Страница 2: ...e Manual H5 60 77 01 Responsible Uwe Laarmann KÜPPERSBUSCH HAUSGERÄTE AG email uwe laarmann kueppersbusch de Tel 0209 401 732 Kundendienst Fax 0209 401 743 Postfach 100 132 Date 23 05 2003 45801 Gelsenkirchen ...

Страница 3: ...6 7 Installing the recirculating air diverter 6 8 Electrical functional components 7 9 Accessing components 9 9 1 Replacing the halogen lighting and the lamp body 9 9 2 Demounting the switch unit 10 9 3 Accessing the mains supply transformer and electronics unit 10 9 4 Demounting the motor and the fan wheel from the KD 957 1 11 9 5 Demounting the motor and the fan wheel of the IKD 1157 1 12 10 Tec...

Страница 4: ...trol keys on the front the desired extraction power can be set The control lights above the keys indicate the set extraction power of the cooker hood The lighting is switched on or off by slightly pressing 3 Programming the air extraction time The factory setting for the extraction time is 10 minutes This time is activated when the control key for the desired power setting is pressed for 2 seconds...

Страница 5: ...an is switched off 5 Metal grease filters Both grease filters are dismantled by pressing the respective lock downwards 6 Charcoal filter For the recirculating air mode you need two activated charcoal filters When the filter effect is run down depending on use up to 12 months they have to be replaced ...

Страница 6: ...tion 7 Installing the recirculating air diverter In the case of the recirculating air mode a recirculating air diverter must be installed so that the cooking fumes extracted can escape through the ventilation openings on the side of the upper chimney Subsequent to installing the upper chimney mounting support A attach the recirculating air diverter B with screws as shown in the illustration Then c...

Страница 7: ...H5 60 53 01 7 For internal use only 8 Electrical functional components Capacitor Holder electric system Transformer 230V 12V Mains connector socket Electronics ...

Страница 8: ...8 H5 60 53 01 For internal use only Conductor insert white empty black orange blue empty brown red Connector ...

Страница 9: ...r bare hands The maximum lamp power is 20W We recommend that you use a dry cloth in order to protect the lamp Replace part A by turning it so that it clicks into place as shown in the illustration In order to demount the entire body of the lamp the grease filters must firstly be removed Then remove component A and press the two plastic flaps of the lower part of the lamp together above the bar C a...

Страница 10: ...it If you loosen the two front metal screws in the bar C you will be able to remove the switch unit on the side above the bar 9 3 Accessing the mains supply transformer and electronics unit Once the lower chimney has been removed all three components are accessible C ...

Страница 11: ...s gently press the hood upwards remove it from the wall mounting support and pull it out towards the front Place the hood on its back on a scrape resistant surface Remove the switch unit as indicated in 9 2 remove the halogen lamps completely as described in 9 1 Loosen the screws 1 and then pull out the mounting plate with the motor and the cables switch and halogen lamps upwards Now loosen the sc...

Страница 12: ...wo screws at the front and remove the front plate After removing the front plate loosen the 4 screws 2 on the left and 2 on the right of the support Then remove the support plate for the motor with the mains supply box the electronics unit and the halogen transformer by means of tilting it to the side Loosen the 4 screws and remove the motor from the support plate Finally remove the 6 screws of th...

Страница 13: ...nt 3 2 1 min speed A 0 74 0 59 0 47 10 Max speed rpm 1700 100 Speed 3 2 1 min speed rpm 1200 1000 800 10 Max T motor C 115 Max temp of operating time at locked rotor C 190 Motor protection C 140 Protection glass I Insulation glass F Usage continuous Capacitor µF 6 3 Admissible ambient temperature C 40 Voltage take off V 190 Modality Test Execution Reference rules EN 60335 1 EN 60335 2 test perform...

Страница 14: ...y Q 785 m h Q max measured 795 m h Efficiency 71 Power W 260 W RPM 1720 VALUES Q m h V m sec HT Pa HDF Pa HSF Pa P W RPM U 1 0 0 439 0 00 439 00 172 2811 632 10 407 61 19 345 81 284 2682 392 6 365 22 76 342 24 203 2501 536 8 297 42 51 254 49 221 2296 646 10 222 61 75 160 25 238 2085 707 11 161 73 85 87 15 249 1911 757 12 118 84 60 33 40 256 1777 795 13 81 93 36 12 36 260 1670 ...

Страница 15: ...e box Entrada de tensión de red Mains connection Control electrónico Electronic control Común Common Luces Lamps Motor Motor 4 Velocidades 4 speeds Transformador Transformer Cable plano Flat cable Mando botonera de funciones Control panel Entrada Entry Salida Exit ...

Страница 16: ...16 H5 60 53 01 For internal use only 12 Wiring diagrams KD 957 1 ...

Страница 17: ...se only 1 RED 2 BROWN 3 BLUE 4 WHITE 5 GREY 6 BLACK 7 ORANGE RED BLACK GREY WHITE BLUE BROWN ORANGE YELLOW 1 2 3 4 5 6 7 RED BLACK V ORANGE BLUE minimal speed ORANGE WHITE 2nd speed ORANGE GREY 3rd speed ORANGE BLACK maximum speed ...