20
H2-120-01-01
For internal use only
Changing the main injectors
♦
Through the mixing pipe of the burner mount the
socket wrench onto the injector and unscrew the
injector using a screwdriver.
♦
Place the new injector into the socket wrench and
screw it in as far as it will go.
Changing the low-flame injectors
♦
Using a suitable screwdriver, remove the low-flame
injectors located on the right side of the axis of the
gas tap.
♦
Fit the new low-flame injectors.
Assembling the hob
♦
Mount glass ceramic hob and, while doing so, pass
the spark plugs, temperature sensors and control
knob pins through the appropriate openings.
♦
Mount burner flange and screw tight.
♦
Insert screws on the housing side again and tighten
the screws evenly and alternately.
♦
Make sure that the changement is clearly marked on
the model identification plate!
Reinstalling the hob
♦
Check gasket.
♦
Insert the rear edge of the hob and carefully lower it.
At the same time press in the clip with both hands.
♦
Press hob downwards until it rests completely on the
worktop.
♦
Place the burner cover, the saucepan support(s) and
attachment carefully in the correct position.
The pivot must click into the notch.
Socket wrench
Main injector
Содержание GKS 324.0-54
Страница 1: ...GB Glass Ceramic Gas Hob GKS 324 0 54 GKS 644 0 54...
Страница 11: ...H2 120 01 01 11 For internal use only 3 Technical Components Exploded View 3 1 GKS 644 0 54...
Страница 12: ...12 H2 120 01 01 For internal use only...
Страница 13: ...H2 120 01 01 13 For internal use only 3 2 GKS 324 0 54...
Страница 14: ...14 H2 120 01 01 For internal use only...