background image

GB

Glass Ceramic Gas Hob

GKS 324.0-54

GKS 644.0-54

Содержание GKS 324.0-54

Страница 1: ...GB Glass Ceramic Gas Hob GKS 324 0 54 GKS 644 0 54...

Страница 2: ...Service Manual H2 120 01 01 Responsible N Kirchmair K PPERSBUSCH HAUSGER TE AG Tel 0209 401 718 Kundendienst Fax 0209 401 743 Postfach 100 132 Date 17 07 2001 45801 Gelsenkirchen...

Страница 3: ...Sensors 15 4 3 Changing of Spark Plugs 15 4 4 Renewing Magnet Insets GKS 324 0 54 and GKS 644 0 54 16 4 5 Renewing Gas Tap of the Cooking Zones 17 5 Wiring diagram GKS 644 0 54 GKS 324 0 54 18 6 Conve...

Страница 4: ...nection R Special accessories LPG injector kit 50 mbar acc No 701 LPG injector kit 30 mbar acc No 702 Injector kit natural gas NL acc No 704 Injector kit natural gas LL acc No 703 The new built in gla...

Страница 5: ...chnical data Gas connection 3 9 kW Electrical connection 0 1 kW ready to plug in Appliance dimensions W x D approx 294 x 519 mm Installation height approx 42 mm Recess dimensions W x D approx 265 x 49...

Страница 6: ...7 Control for simmering burner 8 Control for right hand top normal burner position 2 9 Control for right hand bottom normal burner position 4 Accessory supplied Cross support for small pots 1 4 Applia...

Страница 7: ...l space for the gas connection is required below the hob The wall connection strip must be made of heat resistant material and must have no sockets in the area around the hob We recommend using a supp...

Страница 8: ...First of all make a clean cut into the worktop observing the indicated dimensions see Installation Dimensions Make sure that the gasket of the hob is properly seated If the worktops are uneven tiles e...

Страница 9: ...H2 120 01 01 9 For internal use only GKS 324 0 54 GKS 644 0 54 30 mm worktop 40 mm worktop Fixing the hob...

Страница 10: ...downwards until it rests completely on the worktop If the worktop cut out should be a little too large it is possible to increase the preliminary spring tension of the clips by screwing them down In c...

Страница 11: ...H2 120 01 01 11 For internal use only 3 Technical Components Exploded View 3 1 GKS 644 0 54...

Страница 12: ...12 H2 120 01 01 For internal use only...

Страница 13: ...H2 120 01 01 13 For internal use only 3 2 GKS 324 0 54...

Страница 14: ...14 H2 120 01 01 For internal use only...

Страница 15: ...accessible 4 2 Changing of Temperature Sensors 1 Remove hob 2 Undo sensor at the gas tap 3 Remove burner 1by lifting the holder 2from burner pipe 3 Carefully lever connection ring 4from below the burn...

Страница 16: ...Magnet Insets GKS 324 0 54 and GKS 644 0 54 1 Disassemble hob 2 Undo thermostat sensor at gas tap 3 Undo aluminium nut 4 Pull magnet inset from the gas tap to the back Assembly is done in reverse orde...

Страница 17: ...sassemble hob 2 Undo gas tap gallery from floor 3 Undo thermo element from gas tap 4 After unscrewing nut pull burner pipe out of gas tap 5 Undo fixing bolts Remove clamps then remove gas tap from gas...

Страница 18: ...20 01 01 For internal use only 5 Wiring diagram GKS 644 0 54 GKS 324 0 54 GKS 324 0 54 GKS 644 0 54 Ignition device Support panel S1 S4 Micro switch T1 Intermittent spark igniter X1 Mains connection t...

Страница 19: ...tap Pull out the mains plug Check the replaceable injectors according to table Table of injector diameters Make sure that the correct injector is used for each burner Dismantle hob and remove glass ce...

Страница 20: ...mic hob and while doing so pass the spark plugs temperature sensors and control knob pins through the appropriate openings Mount burner flange and screw tight Insert screws on the housing side again a...

Страница 21: ...regular flame aspect also in low setting Provide respective nameplates for the newly set gas type in an appropriate location 6 4 Injector Diameter Injector marking main injector low setting injector...

Страница 22: ...Propane G 30 31 Butane Butane Propane G 30 Category mbar mbar mbar mbar mbar mbar mbar mbar Germany DE 20 20 50 II2ELL3B P Denmark DK Finland FI Sweden SE Iceland IS Norway NO 20 28 30 II2H3B P Nether...

Страница 23: ...ble of Gas Connection Pressure Ranges The gas appliance must not be put into service if the gas connection pressure is outside the specified ranges Gas type Caloric value Hs 15 C MJ m3 kWh m3 MJ kg kW...

Страница 24: ...ot allowed to use disks on the burners Using pots with appropriate diameters prevents the pots from getting to near to the control knobs which could result in heating up or damage of the knobs Do not...

Страница 25: ...ctions of the cleanser or cleanser manufacturer concerned Even heavy soiling can be cleaned with a cleanser and enough water Wipe dry with a cloth 8 3 Burner Covers and Saucepan Supports Do not use an...

Отзывы: