Then insert the clips into the worktop cut-out
as shown in the figures shown in the diagram,
observing the clearances indicated. It is not
necessary to adjust the height due to the hori-
zontal stop motion device.
If the worktop cut-out should be a little too
large, it is possible to increase the preliminary
spring tension of the clips by screwing them
down.
–
Install the cooking area on the left as shown (1), align it (2) and
fasten it (3).
You only require the enclosed tension ele-
ments S if you are fitting the cooking area
into worktops made of granite, marble or si-
milar materials.
Electrical connection
The built-in cooking area must be connected to the mains supply
by a qualified electrician who is authorized to carry out such
work.
Both legal wiring regulations and the requirements of your local
electricity supply board must be fully complied with.
When connecting the appliance it must be ensured that there is a de-
vice which makes it possible to disconnect it from the mains at all poles
with a contact opening width of at least 3 mm. Line-protecting switches,
fuses or contactors are suitable cut-out devices.
When connecting and repairing the appliance disconnect it from the
electricity supply with one of these devices.
The appliance must be installed in such a way that it is completely con-
tact-voltage proof.
It must not be possible to touch nonconducting parts when the applian-
ce is installed.
The earthed conductor lead must be sufficiently long so that, in the
event of failure of the strain relief, it is not subjected to strain until after
the live wires of the connection cable.
Any superfluous cable must be removed from the installation area be-
neath the appliance.
Electrical connection
Permanent connection by means of an oven
connection socket.
Connection diagram
is depicted on the underside of the applian-
ce, suitable for the various types of mains.
Connection data
Permanent connection 400 V 3 N
∼
50 Hz
(AC 230 V in UK)
Voltage of heating element: 230 V
400 V 3 N
∼
safety current 16 A
400 V 2 N
∼
safety current 20 A
230 V 1 N
∼
safety current 25 A
Connection cable
Use H 05 RR-F or H 07 RN-F.
The cable must be no shorter than 2 m.
Granite
24
EKE 807.2