10
11
KCHS4852 IX
KCHS4852 WH
EN
visor cooker hood
2. OPERATING INSTRUCTIONS
2.1. Product Description
• The room should be well-ventilated when the cooker hood is used
at the same time as appliances burning gas or other fuels.
• There is risk of fire if the cleaning is not carried out in accordance
with the instructions.
• The air must not be discharged into a flue that is used for exhausting
fumes from appliances burning gas or other fuels.
• When the range hood is located above a gas appliance, the minimum
distance between the supporting surface for the cooking vessels on
the hob and the lowest part of the rang hood that distance must be
at least 65 cm.
• If the supply cord or the LED bulb are damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
• Regarding the cleaning and maintenance of the appliance, please
refer to the section <Cleaning> and <Maintenance>.
2.1.1 Installation Instructions
Method A:
If you have an outlet to the outside, your cooker hood
can be connected as below picture by means of an
extraction duct (enamel, aluminium, flexible pipe or
non-flammable material with an interior diameter of
120mm).
1.
Before installation, turn the unit off and unplug it
from the outlet.
2.
The cooker hoods should be placed at a distance of 65-75cm from
the cooking surface for best effect. See Pic 1.
Pic 1
Pic 2
3.
To install onto the wall, drill 2 holes of Ø 8mm on a suitable place
according with the centre distance of hole in the back of the cooker
hood. See Pic 2
4.
Insert the wall plugs into the holes.
5.
Insert the ST4*30mm screws into the wall plugs and tight.
6.
Put up the cooker hood onto the fixed screws.
7.
Then use the attached accessories enclosed to turn the safety
screws into the two holes of inside the hood, and then fix the
screws to tighten the hood onto the wall. See picture below.
8.
Put the expansion pipe on the outlet, then lead it to outdoor, or
use the outlet cover to seal the outer outlet and open the inner
exhaust valve.
Note:
the expansion pipe is not supplied.
Method B:
1.
Drill 4 holes of Ø 6mm at the bottom of the hanging cupboard. See
pic below.
2.
Install the cooker hood on the bottom of the cupboard, tighten the
cooker hood with enclosed M4 flat washer.
3.
Put the expansion pipe on the outlet, then lead it to outdoor. Note:
the expansion is not supplied.
Note:
There are 2 methods for ventilation, including ‘horizontal venti-
lation’ and ‘ vertical ventilation’. Please pay attention to the ventilation
method when installation.