Gateway EtherCAT
17
4.6 Connecting the Power Supply
To connect the gateway component to the power supply, you need a spring-loaded terminal (e.g.
Metz-Connect SP995xxVBNC).
Lay a separate supply line to the power supply for each gateway component and make sure that
the GND are connected to each other at the power supply. Connect FE to PE with low resistance.
NOTICE
Connect the two gateway components to the power supply.
a) Ensure in particular that no potential differences occur between the GND pins (2).
Pin assignment:
Pin
Assignment
1
24 V for module supply
3
1
2
4
2
GND
3
Do not connect!
4
Functional earth