![Kühtreiber 150 RS Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/kuhtreiber/150-rs/150-rs_user-manual_2009599036.webp)
36 |
Setting the ANTI STICK function
(when the electrode is stuck)
The function reduces the welding voltage to 5 V when
evaluating the short-circuit at the output terminals
(when the electrode is stuck to the welded material),
thus allowing the electrode to easily detach from the
welded material. The function can be activated or de
-
activated. Press the SET button for about 5 seconds until
the display shows „the AS symbol. There are two options:
AS 0
function is disabled
AS 1
function is active
Setting the V.R.D. function
(decrease of output voltage)
This is a MMA security system only. When the function
is activated, the output voltage is reduced to 15 V. This
function is used for underwater or high humidity envi
-
ronments. To activate the function, turn off the machine,
press the MET button, hold the button on and switch on
the machine with the main switch. The corresponding
function value (ON / OFF) appears in the display. In the
case of ANALOG RS, only the LED indicator is indicated.
When the function is active, the warning light is on.
Otherwise, the function is inactive.
Digital TIG LA RS - ON
Digital TIG LA RS - OFF
PRESS
Analogue RS - ON
Analogue RS - OFF
EN