EL92-180/205/230
36
6. - Putting into service
KN007CGB_F
Power tiller
Models 205 - 230:
The lower coupling yokes can be placed in
2 different positions:
• Category 1 linkage:
L = 683 mm (2’2’’) (approximately).
• Category 2 linkage:
L = 825 mm (2’8’’) (approximately).
Adjusting the category
- Loosen screw (1).
- Remove the 2 nuts (3).
- Position lower coupling yokes (4) opposite free
holes.
- Tighten the 2 nuts (3):
• Torque: 21 daNm (155 lbf ft).
- Adjust sliding guard (2) position to fully cover
machine front part between lower coupling yokes
and machine ends:
• Distance D between sliding guard and lower
coupling yokes must not exceed 60 mm (2.4’’).
- Tighten screw (1):
• Torque: 8.5 daNm (63 lbf ft).
- Proceed the same way on the other side.
L
L
4
3
2
1
3
D
Содержание EL92-180