- 39 -
b) POWER TILLER with larger diameter L- blade rotor
(fig. 56 and photo 57)
The blades can be fitted in two different ways, depending on the job to get done :
- 3 pairs of blades per flange
3 right blades (D) and 3 left blades (G) (as fitted at factory)
- 2 pairs of blades per flange
2 right blades (D) and 2 left blades (G)
To recognise if blades are right or left, point the cutting
edge in the direction of rotation (F) and note the
direction of their curved portion.
A = machine forward direction
To fit blades helicoidally, proceed as follows :
- Always start fitting each flange with a left blade,
placing it opposite mark (R), shown by a chamfer or
a hollow (see fig. 56),
- all blades should be fitted on the left face of the
flanges (see photo 57).
- Fixing bolt heads should face the blades, washers
and nuts should face the flanges.
MODEL
250
300
Number of rotor flanges
11
13
TYPE OF
TYPE OF
NUMBER OF
FORMATION
BLADES
BLADES
2 pair
RIGHT
20
24
formation
LEFT
20
24
3 pair
RIGHT
30
36
formation
LEFT
30
36
NUMBER OF BLADES
End blades :
depending on the way the blades have been fitted (2 or 3 pairs of blades per flange), the left end
flange is fitted with 2 right blades diametrically opposite to each other or 3 right blades. Likewise, the right end flange
will be fitted with 2 left blades diametrically opposite to each other or 3 left blades (photo 57).
Tighten nuts to a torque of 30 daNm / 220 ft.lbs
.
56
57
Содержание EL 142
Страница 1: ...ASSEMBLY OPERATOR S MANUAL EL 142 POWER TILLER CULTITILLER CULTIPLOW No 95461CGB A 08 2003...
Страница 11: ...9 2 3 4 5 6 7 8...
Страница 50: ...N O T E S...