Mower conditioner
60
ALTERNA400
Maintenance and storage
Changing angle gearbox oil
Upper gearbox:
- Remove dipstick plug (1).
- Use an oil syringe to drain the angle gearbox.
- Pour the correct oil quantity and quality through the
opening of the filler plug (1).
- Check oil level in upper gearbox:
• The "MAX" level corresponds to the mark on the
dipstick plug.
• The "MIN" level corresponds to the end of the
dipstick plug.
- Clean and reinstall dipstick plug (1). Replace it if
necessary.
Before draining oil, operate the machine for a
few minutes so that the oil warms up.
The upper gearbox is lubricated with 1.75 L (0.46 US gal) of SHELL SPIRAX extreme-pressure gear oil
with SAE 80W90 viscosity grade API and GL5.
When draining and refilling, it is recommended to use either a mineral base oil with viscosity grade
SAE 80W90 and API grade GL5, or a synthetic base oil, type PAO (Poly-Alpha-Olefins) with a viscosity
grade equivalent to SAE 80W90.