Step 1 - Determine Opening Side
1. Stand the ‘Door Glass Assembly’ (CRV-S) upright,
leaning against a wall with the curved face (the
outside) coming away from the wall, ensuring all
contact corners are protected. Determine if the
shower enclosure is to be opening from the left or
right (the handle will be next to the wall when in the
closed position).
Parts List
Installation Pack
1 x CRV-F
Fixed Glass Panel
2 x M54-01
Height Adj. Base
2 x M54-02
Height Adj. Cam
2 x M56-01
Wall Jamb Top
Cap
2 x M56-02
Comp. Chnl. Top
Cap
6 x 6mm
Wall Plugs
12 x No.8x30 PH
S/S Screws
2 x No.4x10 CSK
S/S Screws
Installation Steps
1 x M97-01
Shim
2 x PlexF05
Glazing Wedge Seal
2. Once the ‘handing’ has been determined, fit the
two ‘Top Roller Assemblies’ to the top corners of the
glass, with the wheels facing the outside. To do this,
the screw is removed using the 3mm Allen key, and
the small casting half and patch pad are placed to the
inside of the glass, before the wheel casting and patch
are placed to the outside of the glass, The screw is
reinserted and tightened.
1 x
Curved Rail Left
1 x CRV-S
Door Glass Assembly
8 x No.6x30 PH
S/S Screws
2 x M276-01
Patch Guide Caps
1 x M73-02
Top Cap Left
1 x M73-01
Top Cap Right
1873 & 1912mm
PlexRF023 Overlap Seals
1 x
Fixed Panel Wall Post
1 x
Door Panel Wall Post
2 x DCM-86-ASM
Top Roller Assembly
1 x DCM-89-R-ASM
Bottom Guide Right
1 x DCM-89-L-ASM
Bottom Guide Left
3. Now take the right and left ‘Bottom Guides’ and
fit to the bottom left and right corners of the glass.
Again removing the screw, and sandwiching the
glass between the two casting and patches pads,
before reinserting the screw and tightening, ensuring
the grooved retaining arms are to the outside and
pointing to the centre.
Step 2 - Remove Angle Compensator Posts
1. Taking the two ‘Wall Post Assemblies,’ unclip and
remove the angled compensator post profile from
each post, retaining them for later steps.
Step 3 - Handing of Unit
1. This stage will determine which side you wish to fit the fixed panel glass, to the left or to the right of
the unit, to suit your installation. Arrange the wall posts into the correct position, either left or right
depending on the door opening and fixed panel.
View From
Outside
Door opening for this example
THIS FACE TO OUTSIDE
THIS FACE TO OUTSIDE
1 x
Curved Rail Right
2 x No.6x12 PH
S/S Screws
2 x DCM-85-ASM
Glass Patch Clamp
Closing Side (for example)
Fixed Side (for example)