background image

1

Issue 01 MAR.19

Pozi-head Screwdriver  

Flat-head Screwdriver 

 

3mm Allen Key - supplied 

Cutting Pliers

Junior Hacksaw 

 

Clear Silicone Sealant 

7mm Masonry Drill Bit  

Drill (Battery or Mains)

Spirit Level          

 

Tape Measure 

Marking Paste (Shoe Polish) 

INSTALLATION INSTRUCTIONS - CURVED OFFSET SIDE ACCESS

Please read these instructions throughout before installing as incorrect fitting will invalidate the guarantee.

If you are unsure about these instructions please contact Kudos Shower Products 01539 564040.

HEALTH & SAFETY WARNING

DUE TO THE WEIGHT & SIZE OF THE GLASS PANEL(s) A MINIMUM OF TWO PERSONS ARE REQUIRED

TO MOVE AND INSTALL THIS ENCLOSURE

For the wall post and fixings use only warm soapy water and damp cloth/ sponge 
on a regular basis. After cleaning please rinse with clean water to remove any 
residue. 

Do not use abrasive scouring powders, chemicals or aerosol cleaners - these may 

result in damage to the surfaces, in particular, the plated component parts.

The glass panels are pre-treated with Life Shield on the inside surfaces only.

Whilst this makes cleaning the glass easier and helps prevent the build up of 
harmful lime-scale and soap deposits, the glass still needs to be maintained on a 

regular basis. We recommend the use of a detergent and aroma free glass cleaner 
(A 50/50 mix of white vinegar and water works well).

DO NOT use strong detergents, abrasive cleaners or abrasive scrubbing 

equipment for cleaning, these can damage the coating.

DO use a squeegee to remove remaining droplets of water from glass after 
showering, any build up of residue can be removed easily using an appropriate 

cleaner and agitation from soft cleaning equipment.

Cleaning - General

Kudos LifeShield Glass Treatment

Important

Check appearance of all product - any defects must be reported to Kudos Shower 

Products before assembly/installation. Claims for imperfections will only be 
accepted prior to assembly/installation.

Any claims made under the terms of the Lifetime Guarantee must be reported to 

Kudos within 21 days of the fault occurring.

Check the enclosure adjustment sizes are suitable for your installation.

Use care when drilling into the walls to avoid hidden pipes or electric cables.

Stage 2

silicone sealant

Stage 1

Shower Tray

Ensure the top of shower tray is 

LEVEL in ALL directions.

Once the tray is installed but 

before the wall tiles are fitted, any 

gap between the tray and the walls 

must be filled with silicone sealant 
flush with the top of the tray.

Once the walls have been tiled but 
before the enclosure is installed, 
the tiles must be silicone sealed to 
the tray all of the way around in 

one continuous bead.

Failure to follow these 
instructions will result in 
leakage problems.

THESE INSTRUCTIONS ARE TO BE LEFT

WITH THE CONSUMER

Tools Required

original

6

original

6

Содержание Original6

Страница 1: ...of white vinegar and water works well DO NOT use strong detergents abrasive cleaners or abrasive scrubbing equipment for cleaning these can damage the coating DO use a squeegee to remove remaining droplets of water from glass after showering any build up of residue can be removed easily using an appropriate cleaner and agitation from soft cleaning equipment Cleaning General Kudos LifeShield Glass ...

Страница 2: ...mbly 8 x No 6x30 PH S S Screws 2 x M276 01 Patch Guide Caps 1 x M73 02 Top Cap Left 1 x M73 01 Top Cap Right 1873 1912mm PlexRF023 Overlap Seals 1 x Fixed Panel Wall Post 1 x Door Panel Wall Post 2 x DCM 86 ASM Top Roller Assembly 1 x DCM 89 R ASM Bottom Guide Right 1 x DCM 89 L ASM Bottom Guide Left 3 Now take the right and left Bottom Guides and fit to the bottom left and right corners of the gl...

Страница 3: ...screw through the relevant holes in white plastic spacer blocks on the wall posts and into each screw port two screws for each corner of frame ensuring these are fully tightened by hand The side of the curved rails with the screwed in stop should be to the fixed glass panel side opposite to the door opening Also ensure that the curved rails are fitted flush with ends of each wall post Door Opening...

Страница 4: ...ing channel shown actual size Narrow Compensating channel shown actual size 1000 SIDE 1000 SIDE 810 SIDE 810 SIDE Wide Compensating channel shown actual size Wide Compensating channel shown actual size 2 For Step 20 identify left or right hand cover cap as appropriate to the top of Wide compensating channel VIEW FROM TOP LEFT HAND INSTALLATION VIEW FROM TOP RIGHT HAND INSTALLATION ...

Страница 5: ...ferent angled top faces in order to help keep the frame supported use the Shim M97 01 supplied On the inside of the enclosure measure the gap between the bottom of the rail and top of the tray select the height required from the shim strip supplied break off and insert under rail at fixed panel clamp position hole drilled on curved rail This will support rail when glass is fitted The shim will be ...

Страница 6: ...ost ensuring the panel is concentric with the rail and vertical to the wall post Tap the plastic profile firmly into groove of clip in extrusion along full length if this is not done the fixed panel glass may interfere with the door glass when this is installed Handing shown for example only Tip Use your foot to steady the bottom of the glass and prevent it slipping off the curved rail 2 Take the ...

Страница 7: ...osts sills to the tray on the inside can result in leakage problems please note that in use water can penetrate into the frame extrusions this has no detrimental effect to the product however this water must be allowed to drain out of the extrusions to the inside Silicone down the wall posts wall junction around the shim and at the bottom between the fixed glass seal and wall post 2 Turn the two r...