FOR MORE DETAILS AND INFORMATION, PLEASE VISIT OUR WEBSITE
WWW.KUCHT.COM
INSTALLATION GUIDE AND USER MANUAL
Trouble shooting Tips
Symptom
Possible Cause Solution
BURNERS
WILL
NOT
LIGHT.
Burner parts or
Igniters maybe
wet,dirty
or
misaligned.
Check that the burner parts are clean,dry
And correctly assembled.Check that the
igniters are clean and dry.
TOP BURNER WILL
NOT STAY LIT
Failed
Thermonuclear
Replace thermocouple
FLAMES DO NOT
BURN
ALL
AROUND
THE
BURNER CAP.
Burner parts
Maybe dirty or
misaligned.
See“Care and Cleaning”instructions.
BURNER FLAMES
ARE
VERY
LARGE
AND
YELLOW.
Burner bezel
Ports are
clogged.
Burner ports or
burner caps are
not positioned
properly.
Range top is
being operated
with the wrong
type of gas.
Regulator is not
installed,is
faulty,or is set
for the wrong
type of gas.
Clean burner be zelring ports with
Straightened paperclip,needle,or wire.
Remove and carefully re
‐
install burner
bezel and caps.
Ensure that the type of range top matches the
gas supply.
Check installation,replace regulator,or set
regulator for proper gas.
IGNITERS ARE
SPARKING BUT
BURNERS
ARE
NOT IGNITING.
Gas shut
‐
off
Valve is in the
“OFF”position.
Turn shut
‐
off valve to the“ON”position.