GENERATOR
GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
2-S17
Pilot Box
1. Continuity should exist between the terminals for each lamp.
2. If there is no continuity, change the lamp.
9Y1211607GRS0020US0
Charge
3
terminal –
4
terminal
Approx. 10
Ω
Water temperature
2
terminal –
8
terminal
Oil pressure
7
terminal –
8
terminal
Glow
1
terminal –
5
terminal
(1) Pilot Box
(2) Charge
(3) Water Temperature
(4) Oil Pressure
(5) Glow