2. Move the lever diagonally ((a), (b), and (c) shown in
the figure), and the first and second segments can
be controlled at once.
(1) Loader / remote control
valve lever
(A) Float
(B) R1
(C) R2
NOTE :
• Move the lever to the “FLOAT” position, and it
will be held there by the detent mechanism. To
use the valve as a floating valve with detents,
connect the hydraulic hoses to ports white and
yellow.
• When taking off hydraulic power from port red,
the flow rate can be adjusted in 2 stages with
the lever.
The flow rate is high at position (R1) and low at
position (R2). Move the lever to position (R1) or
(R2) depending on the attachment in use.
3. Valve lock
WARNING
To avoid personal injury or death from crushing:
• Do not utilize the valve lock for machine
maintenance or repair.
• The valve lock is to prevent accidental actuation
when implement is not in use or during
transport.
The control valve is equipped with a valve lock feature.
The control valve is locked in the
“LOCK”
position.
The lock is not intended and will not prevent a leak
down of the implement during the period of storage.
(1) Lock lever
(A) Unlock
(B) Lock
HYDRAULIC UNIT
DUAL REMOTE HYDRAULIC CONTROL SYSTEM [B2401DT ONLY]
48
B2401DT, B2401DTWO, B2401DTN
Содержание B2401DT
Страница 6: ......
Страница 17: ...SAFETY LABELS SAFE OPERATION B2401DT B2401DTWO B2401DTN 11...
Страница 18: ...SAFE OPERATION 12 B2401DT B2401DTWO B2401DTN...
Страница 19: ...SAFE OPERATION B2401DT B2401DTWO B2401DTN 13...
Страница 20: ...SAFE OPERATION 14 B2401DT B2401DTWO B2401DTN...
Страница 21: ...SAFE OPERATION B2401DT B2401DTWO B2401DTN 15...