5 Commissioning and Operation
Kübler Group
30 - EN
HB Modbus Interface - R67048.0002 - 02
This parameter configures the total number of singleturn and multiturn measuring steps. A
factor is used for the maximum physical resolution This factor is always < 1. When reaching the
defined number of measuring steps, the encoder resets itself back to zero (see Limitation).
Values range: TMR 1 … max. physical resolution (4294967296) 32 bits
Default setting: 33554432 (25 bits)
5.7.2.12 Register 281 Scaling Function
Scaling active
0 = off
1 = on, Default = off
Preset delay: 100μs
Position check after preset: yes (internal)
Response delay after Preset update execution command:
15 ms required for the saving process
5.7.2.13 Register 282 Write Delay Prescaler After Request From PLC
Permitted prescaler delay values 1 … 32
Preset delay:
1 = (1*t3.5) = 1750μs
2 = (2*t3.5) = 3.5ms
Max. delay 32 = (32*t3.5) = 56 ms for baud rate > 9600, 128 ms for baud rate 9600
Position check after preset: yes (internal)
Response delay after Preset update execution command:
15 ms required for the saving process