9.3 Disposal
Always dispose of unusable or irreparable devices in compliance with the waste disposal regulations
in force. We will be glad to help you for disposing of these devices. Contact us.
9.4 Service Address
Kübler Group
Fritz Kübler GmbH
-ServiceCenter-
Schubertstrasse 47
D-78054 Villingen-Schwenningen
Germany
10. Technical data
General technical data of the safety-oriented Sine-Cosine interface
SinCos interface
Max. frequency -3dB
400 kHz
Short-circuit resistance
yes
Pulse rate
1024 / 2048 ppr
Offset
2,5 V (+/- 100 mV)
Offset difference A to B
Max. 25 mV
Amplitude
1 Vss (+/- 10%)
Amplitude difference A to B
Max. 40 mV
Terminating resistor
120 ohm
Phases position
90° (+/- 12°)
Characteristic safety values for the Sendix
®
SIL 58xxFS2 and 70xxFS2 encoders
Characteristic safety values
Relevant standards
EN ISO 13849-1 / EN 61800-5-2, EN 61508
Classification
PLd / SIL 2
System structure
2-channel (cat. 3 / HFT = 1)
PFH
d
value
2,16 x 10
-8
h
-1
Service life
20 years