5 Commissioning and Operation
Kübler Group
34 - EN
Manual IO-Link interface - R67071.0002 - 02
In-
dex
(hex)
In-
dex
(dec)
Su-
bind
ex
Object
name
Ac-
cess
Lengt
h
Data
type
Values
Remark
BLOB_ID.
(Only available in
bootloader mode.)
Manufacturer-specific
In-
dex
(hex)
In-
dex
(dec)
Object name
Ac-
cess
Length
Data
type
Values
(default bold)
Remark
0040 64
Position value
R
4 bytes
uint32
0..(TMR-1)
0041 65
Position format
R/W
1 byte
uint8
0: Counts
Is always Counts
0042 66
Position lower
limit
R/W
4 bytes
uint32
0..(TMR-1)
Position
lower limit <=
Position
upper limit
0043 67
Position upper
limit
R/W
4 bytes
uint32
0..
(TMR-1)
Position
upper limit >=
Position
lower limit
0045 69
Position limit
control
R/W
1 byte
uint8
0: Position limit
control disabled
1: Position
limit control
enabled
If enabled:
When the position
value drops below/
exceeds the limit
values, the warning
flag is set
004C 76
Raw position
R
8 bytes
uint64
MT: 0... (2
32
-1)
ST: 0... (2
14
-1)
Unscaled, without
offset, with count-
ing direction
004E 78
Counting
direction
R/W
1 byte
uint8
0: clockwise
(CW)
1: counter-
clockwise
(CCW)
Looking at the
shaft
0050 80
Preset value
R/W
4 bytes
uint32
0
..(TMR-1)