4 Installation
Kübler Group
12 - EN
Manual IO-Link interface - R67071.0002 - 02
132123403
Description
Characteristics
1
Power supply unit
Rated voltage: 24 V DC ±1% tolerance
2
Control line:
Power supply unit – IO-Link Master
Length: 10 m Wire cross-section: 0.75 mm²
3
IO-Link Master
Voltage drop: 0,5 V Rated current: 100 mA
4
Control line:
IO-Link Master – IO-Link Device 1
Length: 15 m Wire cross-section: 0.35 mm²
5
IO-Link Device 1
Rated current: 200 mA Rated voltage: 19 ... 30 V
6
Control line:
IO-Link Master – IO-Link Device 2
Length: 15 m Wire cross-section: 0.35 mm²
7
IO-Link Device 2
Rated current: 100 mA Rated voltage: 19 ... 30 V