R60076.0002
–
Index 1
Page 8 / 24
Electrical Connections
The terminal screws should be tightened with a slotted screwdriver (blade width 2mm).
DC Power Supply
The device is supplied with a DC voltage between 9 ... 30 VDC via terminals 1 and 2 of X1. The
current consumption depends on the level of the supply voltage and the settings and is approx.
35 mA without load from the sensor supply and additional on the extracted encoder current at
the auxiliary voltage output.
All GND terminals are internally interconnected.
Auxiliary Voltage Output
At terminal 8 and 9 of X4 the auxiliary voltage as encoder / sensor supply is +5.5 VDC and can
be charged with max. 250 mA.