DIL1 Front
8-pole
Narrow Z puls e (1/4 output- or input-period)
4
5
OFF
ON The Z pulse is generated from the input signal A/B. Each input period
generates one count for the Z divider.
The Z pulse width at the output corresponds to 1/4 period of the pulse width of
the input signal A/B (Only applicable to input signals A/B 90°, DIL1/6 = OFF).
ON
OFF The Z pulse is generated from the output signal A/B. Each output period
generates one count for the Z divider.
The Z pulse width at the output corresponds to 1/4 period of the pulse width of
the output signal A/B (Only applicable to output signals A/B 90°, DIL1/7 =
OFF).
Reset the Z divider with ZERO_Z Signal
The Z divider can be reset by applying a high signal to the control input ZERO_Z.
The reset will act immediately and as long as the signal is applied.
Depending on the direction of the A/B track, the next Z pulse appears immediately after the
reset or according to the set division ratio (not at the independent Z divider).
The reset of the Z divider can also be performed in case of automatic generation of the Z pulse.
By setting the Z-divider = all OFF, the setting of the ZERO_Z input causes an immediate zero
setting of the output ZOUT (see level conversion Z pulse).
Note the special case in which the ZERO_A signal can also set the Z output to zero (see Setting
to zero of the A/B divider with ZERO_A signal)