Safety Instructions and Responsibility 

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition - in accordance to the 

Technical Specifications

” (see chapter 

10

). The device is not 

suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 
standard. 
 

 

Installation 

The device is only allowed to be installed and operated within the permissible temperature 
range. Please ensure an adequate ventilation and avoid all direct contact between the device 
and hot or aggressive gases and liquids.  

Содержание FT.1D-1D

Страница 1: ...r the direction of rotation A B 90 A B Direction and vice versa Adjustable division ratio of directional A B pulses Adjustable division ratio for the Z pulse Reset of the Z divider by external input d...

Страница 2: ...02a AF MBO Dez 2019 FT 1D 1D extension Legal notices All contents included in this manual are protected by the terms of use and copyrights of Fritz K bler GmbH Any reproduction modification usage or p...

Страница 3: ...ut and output configuration 12 Level converter A B Pulse A B Divider All OFF 13 Input Output Mode Converter A B Divider All OFF 13 Adjustable divider A B 13 Setting the A B Divider at A B Dir to A B 9...

Страница 4: ...minor differences between the unit and the descriptions in operation manual The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will...

Страница 5: ...that all connections and wires are firmly seated and secured in the screw terminals All inclusively unused terminals must be fastened by turning the relevant screws clockwise up to the stop Overvolta...

Страница 6: ...HTL Single RS422 HTL Diff HTL Single TTL Frequency Max 300kHz 1MHz 1MHz 350kHz 350kHz Output RS422 DSUB HTL clamps Parallel outputs clamps Only 1 output Encoder supply 5 5V 130mA 5 5V 250mA Temperatur...

Страница 7: ...ustable ratio 1 1 to 1 4096 Division of the Z pulse with adjustable ratio 1 1 to 1 256 External HTL signals for various functions Implementation between the two types of representations for the direct...

Страница 8: ...and 2 of X1 The current consumption depends on the level of the supply voltage and the settings and is approx 35 mA without load from the sensor supply and additional on the extracted encoder current...

Страница 9: ...inal 2 7 of X4 3 pulse inputs are available for HTL TTL RS422 signals The unused inputs must be open HTL single ended vs HTL differential or terminated unused Z track in RS 422 or HTL differential for...

Страница 10: ...to contact bouncing will be eliminated Pulse output Depending on the DIL switch setting the pulses are available in HTL or RS 422 format at the outputs of screw terminal X3 and are independent of the...

Страница 11: ...2 2 OFF The DIL switch DIL3 right 3 pin can be used to select the corresponding channel If the DIL3 1 contact is set to OFF no errors are evaluated on the A A line DIL3 2 refers to the line B B and DI...

Страница 12: ...A B OFF ON Z pulse length ynchronized with AOUT BOUT ON OFF Z pulse length synchronized with AIN BIN OFF OFF Z pulse length 1 Z Puls a depending on A B ON Input Mode A B Dir Pulse Direction OFF Input...

Страница 13: ...on the DIL switches DIL5 and DIL6 of the divider A B are all set to OFF the following signal characteristics are set up at the output Case 1 Input A B 90 Output A B Dir DIL1 6 OFF DIL1 7 ON with A B D...

Страница 14: ...OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF value 3 1 8 OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF value 4 1 10 ON OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF value 5 1 12 OFF etc OFF OFF OFF OFF OFF...

Страница 15: ...FF value 1 1 2 OFF ON OFF OFF OFF OF F OFF OFF OFF OFF OFF OFF value 2 1 3 ON ON OFF OFF OFF OF F OFF OFF OFF OFF OFF OFF value 3 1 4 OFF OF F ON OFF OFF OF F OFF OFF OFF OFF OFF OFF value 4 1 5 ON OF...

Страница 16: ...R60076 0002 Index 1 Page 16 24 Example Input A B 90 output A B 90 with A B division 1 3 setting DIL6 5 OFF ON OFF Example Input A B 90 output A B 90 with A B division 1 3 setting DIL6 5 OFF ON OFF...

Страница 17: ...e Depending on the direction of the input signals the next split A B pulse appears immediately after the reset or after the set division ratio The length of the ZERO_A pulse has to be greater than the...

Страница 18: ...ng as there is a high level at the control input The Z pulse can be trimmed by switching Setting the Z Divider The programming of the Z divider is subject to the same rules as the programming of the A...

Страница 19: ...e at the output can fluctuate around an input or output period not with DIL1 5 DIL1 4 ON DIL1 Front 8 pole Wide Z pulse a full encoder turn 4 5 ON ON The pulse width at the output corresponds to the f...

Страница 20: ...ulse at the output would have to appear after 666 666 pulses which is not physically possible Independent Z Divider The Z divider works independently of the A B track the directional evaluation of the...

Страница 21: ...pplicable to output signals A B 90 DIL1 7 OFF Reset the Z divider with ZERO_Z Signal The Z divider can be reset by applying a high signal to the control input ZERO_Z The reset will act immediately and...

Страница 22: ...R60076 0002 Index 1 Page 22 24 Dimensions...

Страница 23: ...vel 1 Low 0 10V High 14 30 V level 2 Low 0 5V High 9 30 V max 350kHz Low 0 0 7V High 2 2 5 V Control inputs Number Format Frequency Response time Load 2 HTL PNP Low 0 5 V High 9 30 V max 20kHz 50 s ma...

Страница 24: ...R60076 0002 Index 1 Page 24 24 K bler Group Fritz K bler GmbH Schubertstra e 47 78054 Villingen Schwenningen Germany Tel 49 7720 3903 0 Fax 49 7720 21564 info kuebler com www kuebler com...

Отзывы: