9
5.2 Switching on the 30 Hz filter
(INP A, INP B)
30 Hz filter off (fmax)
30 Hzfilter on
Count input and count
direction input
INP A: Count input
INP B: Count direction input
Differential input
IINP A: count input adding
INP B: count input subtract-
ing
Totalising
INP A: count input adding
INP B: count input adding
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with pulse
doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted
Quadrature input with pulse
quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
and INP B will be counted.
For the frequency
measurement, INP C may
be operated independently
of the counter input modes.
5.3 Input mode
english
5.4 Multiplying factor
(counter)
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
5.6 Decimal point
(counter)
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
5.5 Dividing factor
(counter)
5.7 RESET Mode
(counter)
manual reset via the red
RESET key
no reset (red RESET key
locked)